Customized hydrogel contact lenses for keratoconus incorporating correction for vertical coma aberration.

机译:定制的圆锥形角膜水凝胶隐形眼镜,结合了垂直彗形像差校正功能。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To study the effects on visual performance of a novel custom hydrogel contact lens, which employs a correction for vertical coma aberration, in keratoconic eyes. METHODS: Six subjects (8 eyes) with mild or moderate keratoconus were recruited for the study. Preliminary measurements included corneal topography, wavefront aberrometry, subjective refraction, visual acuity (VA) and 50% contrast VA. Based on the aberrometry data, customized lenses were made and fitted to the subjects. Evaluation of the on-eye performance of the lenses was carried out, including wavefront aberrometry, over-refraction, VA and 50% contrast VA. In two of the subjects, both eyes were fitted with the customized lenses, and binocular performance was evaluated. RESULTS: Monocular visual performance with a 4 mm pupil, with the lenses worn, was improved, and reached the mean values of -0.003 (LogMar units) of 100% high contrast VA, and 0.049 (in LogMar units) of 50% contrast VA. Vertical coma aberration and total higher-order aberrations (HOAs) were reduced (naked eyes: -0.64 +/- 0.21 root mean square (rms) of vertical coma and 0.86 +/- 0.15 rms of total HOAs; with the lenses worn: -0.29 +/- 0.23 rms of vertical coma and 0.57 +/- 0.17 rms of total HOAs, all for a 4 mm pupil). Binocular VA results from two of the subjects were on average -0.040 (LogMar units) 100% high contrast acuity and -0.060 (LogMar units) 50% contrast visual acuity. CONCLUSIONS: Customized hydrogel contact lenses implementing correction of vertical coma, have been found to improve both monocular and binocular visual performance of eyes affected with mild or moderate keratoconus.
机译:目的:研究一种新颖的定制水凝胶隐形眼镜对视力的影响,该隐形眼镜采用了校正圆锥角膜垂直彗形像差的方法。方法:招募了6例轻度或中度圆锥角膜受试者(8只眼)进行研究。初步测量包括角膜地形图,波前像差法,主观验光,视力(VA)和50%对比度VA。根据像差数据,制作定制的镜片并将其安装到受试者身上。进行了镜片在眼上的性能评估,包括波前像差,超折射,VA和50%对比度VA。在其中两个受试者中,两只眼睛都装有定制的镜片,并评估了双眼性能。结果:在佩戴4毫米瞳孔的情况下,单眼视觉性能得到改善,并且达到100%高对比度VA的平均值-0.003(LogMar单位)和50%对比度VA的平均值为0.049(LogMar单位) 。垂直彗形像差和总的高阶像差(HOA)减少(裸眼:垂直彗形像差-0.64 +/- 0.21均方根(rms)和总HOA的0.86 +/- 0.15 rms;配戴眼镜:-垂直昏迷的0.29 +/- 0.23 rms和总HOA的0.57 +/- 0.17 rms(均适用于4 mm瞳孔)。来自两个受试者的双眼VA结果平均为-0.040(LogMar单位)的100%高对比度视敏度和-0.060(LogMar单位)的50%对比度视敏度。结论:定制的可矫正垂直昏迷的水凝胶隐形眼镜可改善轻度或中度圆锥角膜病患眼的单眼和双眼视觉性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号