...
首页> 外文期刊>Ophthalmology >Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses: a prospective randomized study.
【24h】

Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses: a prospective randomized study.

机译:植入非球面和球形人工晶状体的眼睛的球差和聚焦深度:一项前瞻性随机研究。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To compare distance-corrected, near, and intermediate visual acuities as a measurement of depth of focus and spherical aberration of eyes implanted with aspheric and spherical intraocular lenses (IOLs). DESIGN: Randomized prospective study. PARTICIPANTS: One hundred twenty eyes of 60 patients with bilateral cataract implanted with 3 IOL models (AcrySof IQ, AcrySof SN60AT [Alcon Laboratories, Fort Worth, TX], and Sensar AR40 [Allergan Surgical, Irvine, CA]). METHODS: Pupil diameter was analyzed by using a Colvard pupillometer (OASIS Medical, Inc., Glendora, CA) under photopic, mesopic, and scotopic conditions. Distance (6 m), intermediate (1 m), and near (0.33 m) visual acuities were measured with distance correction in place 90 days after surgery. Wavefront analysis (LadarWave; Alcon Laboratories) was performed using 5-mm and measured photopic pupil diameter at 30 and 90 days after surgery. MAIN OUTCOME MEASURES: To evaluate spherical aberration and depth of focus (by means of distance-corrected near and intermediate visual acuity) in patients implanted with aspheric and spherical IOLs. RESULTS: Photopic pupil sizes in each group were similar at 30 days after surgery. At 90 days after surgery, mean logarithm of the minimum angle of resolution distance-corrected near visual acuity (+/-standard deviation [SD]) was 0.50+/-0.20 in the AcrySof IQ group, 0.38+/-0.17 in the AcrySof SN60AT group, and 0.45+/-0.16 in Sensar AR40 group. Mean spherical aberration values (+/-SD) were 0.03+/-0.05 microm in the AcrySof IQ group, 0.24+/-0.04 microm in the AcrySof SN60AT group, and 0.14+/-0.07 microm in the Sensar AR40 group. The AcrySof IQ group showed a statistically significant lower induction of spherical aberration and worse distance-corrected near visual acuity. The AcrySof SN60AT group showed statistically significant higher mean spherical aberration values and better distance-corrected near and intermediate visual acuity. CONCLUSIONS: The reduction of total spherical aberration after aspheric IOL implantation may degrade distance-corrected near and intermediate visual acuity.
机译:目的:比较距离校正的,近距离和中间的视敏度,作为植入非球面和球面人工晶状体(IOL)的眼睛的焦深和球差的度量。设计:随机前瞻性研究。参与者:60例双侧白内障患者的120只眼中植入了3种IOL模型(AcrySof IQ,AcrySof SN60AT [Alcon Laboratories,Fort Worth,TX]和Sensar AR40 [Allergan Surgical,Irvine,CA])。方法:使用Colvard瞳孔计(OASIS Medical,Inc.,Glendora,CA)在明视,中视和暗视条件下分析瞳孔直径。术后90天,通过距离校正测量距离(6 m),中间(1 m)和附近(0.33 m)视力。使用5-mm进行波前分析(LadarWave; Alcon Laboratories),并在手术后30天和90天测量明视瞳孔直径。主要观察指标:评估非球面和球面人工晶体植入患者的球面像差和焦深(通过距离校正的近视和中视)。结果:术后30天,每组的瞳孔大小均相似。手术后90天,AcrySof IQ组的最小距离校正近视力的平均对数(+/-标准偏差[SD])为0.50 +/- 0.20,AcrySof IQ组为0.38 +/- 0.17 SN60AT组,Sensar AR40组为0.45 +/- 0.16。 AcrySof IQ组的平均球差(+/- SD)为0.03 +/- 0.05微米,AcrySof SN60AT组的平均球差为0.24 +/- 0.04微米,Sensar AR40组的平均球差为0.14 +/- 0.07微米。 AcrySof IQ组在统计学上显示出球面像差的诱导显着降低,而近视力校正的距离更差。 AcrySof SN60AT组显示出统计学上显着较高的平均球差值,并且在近,中视力方面进行了距离校正。结论:非球面人工晶状体植入后总球面像差的减少可能会降低距离校正后的近视力和中视力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号