PURPOSE: To determine incision sizes for 6-mm optic foldable intraocular lenses (IOLs) implanted with injector systems. DESIGN: Nonrandomized, prospective clinical study. PARTICIPANTS: One hundred fifty eyes of 150 patients with cataract and without other anterior segment pathological features or previous eye surgeries. INTERVENTION: We performed implantation of foldable IOLs with sharp optic edges and 6-mm total optic diameter with their recommended injector systems and cartridges: (1) Alcon MA60BM with Monarch II/cartridge A, (2) Alcon SA60AT with Monarch II/cartridge B, (3) Alcon SA60AT with Monarch II/cartridge C, (4) AMO AR40e with Unfolder Sapphire, (5) AMO AR40e with Unfolder Emerald, and (6) AMO Clariflex with Unfolder Silver. With every combination, 25 IOLs were implanted. MAIN OUTCOME MEASURES: We measured incision width before and after phacoemulsification as well as before and after IOL implantation using a Kohnen caliper. RESULTS: The tunnel width (in millimeters; +/- standard deviation) for each combination before and after IOL implantation, respectively, was (1) 3.61 (+/-0.12) and 3.74 (+/-0.15), (2) 3.31 (+/-0.12) and 3.44 (+/-0.16), (3) 2.88 (+/-0.11) and 2.96 (+/-0.11), (4) 3.37 (+/-0.12) and 3.52 (+/-0.09), (5) 2.99 (+/-0.16) and 3.11 (+/-0.14), and (6) 3.06 (+/-0.12) and 3.15 (+/-0.11). The incision sizes before and after implantation for (3) were significantly smaller than all other combinations. Combinations (2) and (4) were not statistically significantly different, but were statistically significantly smaller in preimplantation and postimplantation incision size compared with combination (1) and were larger compared with combinations (5) and (6). However, the relationship of incision size and effective IOL optical zone differed: AR40e (Unfolder Sapphire) < MA60BM < Clariflex < AR40e (Unfolder Emerald) < SA60AT with both Monarch II B and C cartridge (greater means better relationship). CONCLUSIONS: Postimplantation incisions sizes of 2.96 to 3.74 mm were determined with 6-mm total optic foldable IOLs using Monarch and Unfolder injector systems. Because the effective optical zone size is different for some of these IOLs, the incision size alone may not be the only relevant factor for optical outcome.
机译:目的:确定植入注射器系统的6毫米光学折叠式人工晶状体(IOL)的切口尺寸。设计:非随机前瞻性临床研究。参与者:150例白内障患者,无其他前段病理特征或先前的眼科手术,共150眼。干预:我们使用其推荐的进样器系统和笔芯对具有锋利的光学边缘和6mm总光学直径的可折叠IOL进行了植入:(1)Alcon MA60BM与Monarch II /墨盒A,(2)Alcon SA60AT与Monarch II /墨盒B。 ,(3)带有Monarch II / C弹匣C的Alcon SA60AT,(4)带有未折叠蓝宝石的AMO AR40e,(5)带有未折叠绿宝石的AMO AR40e和(6)带有未折叠银的AMO Clariflex。每种组合都会植入25个IOL。主要观察指标:我们使用Kohnen卡尺测量了超声乳化术前后,以及人工晶体植入前后的切口宽度。结果:IOL植入前后每种组合的隧道宽度(毫米; +/-标准偏差)分别为(1)3.61(+/- 0.12)和3.74(+/- 0.15),(2)3.31 (+/- 0.12)和3.44(+/- 0.16),(3)2.88(+/- 0.11)和2.96(+/- 0.11),(4)3.37(+/- 0.12)和3.52(+/- 0.09),(5)2.99(+/- 0.16)和3.11(+/- 0.14),以及(6)3.06(+/- 0.12)和3.15(+/- 0.11)。 (3)植入前后的切口尺寸明显小于所有其他组合。组合(2)和(4)在统计学上没有显着差异,但与组合(1)相比,植入前和植入后切口的大小在统计学上显着较小,而与组合(5)和(6)相比则更大。但是,切口尺寸与有效IOL光学区之间的关系不同:AR40e(展开式蓝宝石)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号