Objective: To evaluate the pathologic findings of 3-piece intraocular lenses (IOLs) with asymmetric or sulcus fixation in pseudophakic cadaver eyes, comparing IOLs with square or round edges on the anterior optic surface. Design: Comparative case series with pathology. Participants: A total of 661 pseudophakic cadaver eyes, obtained from eye banks within the United States, implanted with different IOLs. Methods: Anterior segment scanning of whole eyes with a high-frequency ultrasound system or high-resolution anterior segment magnetic resonance imaging followed by gross examination. Selected eyes were processed for complete histopathologic analysis. Main Outcome Measures: Findings from imaging, gross, and histopathologic evaluation that could be related to out-of-the-bag fixation of the lenses. Results: Of 661 pseudophakic cadaver eyes obtained, 13 had 3-piece hydrophobic acrylic IOLs with anterior and posterior square optic edges, and 14 had 3-piece lenses with anterior round edges (13 silicone lenses and 1 hydrophobic acrylic lens) without symmetric in-the-bag fixation. These 27 selected eyes were processed for complete histopathologic analysis. Gross findings in both groups were composed of IOL decentration and tilt, pigmentary dispersion within the anterior segment and on the IOL surface, and iris transillumination defects. Histopathology of the 14 eyes with 3-piece IOLs with round anterior optic edges showed mild focal disruption of the iris pigmented layer and loop protrusion/erosion in the ciliary sulcus. Additional changes observed in the 13 eyes with square anterior optic edge IOLs included iris changes, such as vacuolization, disruption and loss of the pigmented epithelial layers, iris thinning and atrophy, synechiae, and pigmentary dispersion within the trabecular meshwork. One eye also exhibited initial signs of optic nerve disc cupping. Conclusions: In this series, pathologic findings were more severe in eyes implanted with 3-piece IOLs with square anterior optic edges, suggesting that IOLs with round anterior edges are more suitable for sulcus fixation.
机译:目的:评估假晶状体尸体眼中不对称或沟内固定的三片式人工晶状体(IOL)的病理结果,比较前视表面具有方形或圆形边缘的IOL。设计:具有病理学的比较病例系列。参与者:共有661枚假眼尸体眼睛,这些眼睛是从美国的眼库获得的,并植入了不同的IOL。方法:采用高频超声系统或高分辨率前段磁共振成像对全眼的前段扫描,然后进行大体检查。选择的眼睛进行了完整的组织病理学分析。主要观察指标:从影像学,肉眼观察和组织病理学评估中发现的可能与晶状体袋外固定有关的结果。结果:在获得的661个伪晶状体尸体眼中,有13个具有三片式疏水性丙烯酸人工晶状体,其前,后方为方形光学镜片边缘;还有14个具有三片式镜的前圆形边缘(13个硅树脂镜片和1个疏水性亚克力镜片),且不对称。袋子固定。对这27只选定的眼睛进行处理,以进行完整的组织病理学分析。两组的总体检查结果均由IOL偏心和倾斜,前节内和IOL表面的色素弥散以及虹膜透照缺陷组成。 14眼具有3片IOL且具有圆形前视边缘的组织病理学显示虹膜色素沉着层轻度局灶性破坏以及睫状沟中环loop突出/侵蚀。在13眼具有方形前屈光性人工晶体的眼中观察到的其他变化包括虹膜变化,例如空泡化,色素上皮层的破坏和丧失,虹膜变薄和萎缩,粘膜粘连和小梁网内的色素分散。一只眼睛还表现出视神经盘拔罐的初步体征。结论:在该系列中,植入具有方形前视边缘的3件IOL的眼睛中,病理学发现更为严重,表明具有圆形前边缘的IOL更适合于沟内固定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号