A new technique for measuring a thermal lens, using a holographic shearing interferometer is presented. This technique was used to measure transient thermal lensing in a laser diode pumped NYAB laser. The measured thermal lensing power was proportional to the pumping laser diode intensity, with a gradient of 1.1 x 10(-1) m-l mm(2)/W. The transient response time of the thermal lens was 1.5 s, this value being consistent with the temporal decline of the second harmonic power. (C) 1997 Elsevier Science B.V. [References: 19]
机译:提出了一种使用全息剪切干涉仪测量热透镜的新技术。该技术用于测量激光二极管泵浦NYAB激光器中的瞬态热透镜。测得的热透镜屈光力与泵浦激光二极管的强度成正比,梯度为1.1 x 10(-1)m-1 mm(2)/ W。热透镜的瞬态响应时间为1.5 s,该值与二次谐波功率的时间下降一致。 (C)1997 Elsevier Science B.V. [参考:19]