Using optical coherence tomography to assess corneoscleral morphology after soft contact lens wear

机译:佩戴软性隐形眼镜后使用光学相干层析成像技术评估角膜巩膜形态

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the use of optical coherence tomography (OCT) for assessing the effect of different soft contact lenses on corneoscleral morphology. METHODS: Ten subjects had anterior segment OCT B-scans taken in the morning and again after 6 h of soft contact lens wear. For each subject, three different contact lenses were used in the right eye on non-consecutive days, including a hydrogel sphere, a silicone hydrogel sphere, and a silicone hydrogel toric. After image registration and layer segmentation, analyses were performed of the first hyper-reflective layer (HRL), the epithelial basement membrane (EBL), and the epithelial thickness (HRL to EBL). A root mean square difference (RMSD) of the layer profiles and the thickness change between the morning and afternoon measurements were used to assess the effect of the contact lens on the corneoscleral morphology. RESULTS: The soft contact lenses had a statistically significant effect on the morphology of the anterior segment layers (p < 0.001). The average amounts of change for the three lenses (average RMSD values) for the corneal region were lower (3.93 ± 1.95 μm for the HRL and 4.02 ± 2.14 μm for the EBL) than those measured in the limbal/scleral region (11.24 ± 6.21 μm for the HRL and 12.61 ± 6.42 μm for the EBL). Similarly, averaged across the three lenses, the RMSD in epithelial thickness was lower in the cornea (2.84 ± 0.84 μm) than the limbal/scleral (5.47 ± 1.71 μm) region. Post hoc analysis showed that ocular surface changes were significantly smaller with the silicone hydrogel sphere lens than both the silicone hydrogel toric (p < 0.005) and hydrogel sphere (p < 0.02) for the combined HRL and EBL data. CONCLUSIONS: In this preliminary study, we have shown that soft contact lenses can produce small but significant changes in the morphology of the limbal/scleral region and that OCT technology is useful in assessing these changes. The clinical significance of these changes is yet to be determined.
机译:目的:评估光学相干断层扫描(OCT)的使用,以评估不同软性隐形眼镜对角膜巩膜形态的影响。方法:十名受试者于早晨进行了前段OCT B扫描,并在软接触镜佩戴6小时后再次进行。对于每个受试者,在非连续日中右眼使用三种不同的隐形眼镜,包括水凝胶球,有机硅水凝胶球和有机硅水凝胶复曲面。在图像配准和层分割之后,对第一高反射层(HRL),上皮基底膜(EBL)和上皮厚度(HRL至EBL)进行分析。层轮廓的均方根差(RMSD)和早晨和下午测量之间的厚度变化用于评估角膜接触镜对角膜巩膜形态的影响。结果:软性隐形眼镜对前节各层的形态具有统计学意义(p <0.001)。与角膜缘/巩膜区的测量值相比,角膜区域的三个透镜的平均改变量(平均RMSD值)更低(HRL为3.93±1.95μm,EBL为4.02±2.14μm)(11.24±6.21) HRL为μm,EBL为12.61±6.42μm)。类似地,在三个晶状体上平均,角膜上皮厚度的RMSD(2.84±0.84μm)低于角膜缘/巩膜区(5.47±1.71μm)。事后分析表明,对于组合的HRL和EBL数据,有机硅水凝胶球镜的眼表变化明显小于有机硅水凝胶复曲面(p <0.005)和水凝胶球体(p <0.02)。结论:在这项初步研究中,我们表明软性隐形眼镜可以在角膜缘/巩膜区域的形态上产生微小但显着的变化,OCT技术可用于评估这些变化。这些变化的临床意义尚待确定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号