...
首页> 外文期刊>Ophthalmic surgery, lasers & imaging: the official journal of the International Society for Imaging in the Eye >The effect of compression on clinical diagnosis of glaucoma based on non-analyzed confocal scanning laser ophthalmoscopy images.
【24h】

The effect of compression on clinical diagnosis of glaucoma based on non-analyzed confocal scanning laser ophthalmoscopy images.

机译:基于非分析共聚焦扫描激光检眼镜图像,压缩对青光眼临床诊断的影响。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND AND OBJECTIVE: To evaluate the effect of different image compression formats of non-analyzed Heidelberg Retina Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany) images on the diagnosis of glaucoma by ophthalmologists. MATERIALS AND METHODS: Thirty-three topographic and reflectance images taken with the HRT representing different levels of disease were transformed using nine different compression formats. Three independent ophthalmologists, masked as to contour line and stereometric parameters, classified the original and compressed HRT images as normal, suspected glaucoma, or glaucoma, and Kappa agreement coefficients were calculated. RESULTS: The Tagged Image File Format had the largest file size and the Joint Photographic Experts Group (JPEG) 2000 format had the smallest size. The highest Kappa coefficient value was 1.00 for all ophthalmologists using the Tagged Image File Format. Kappa values for JPEG formats were all in the range of good to excellent agreement. Kappa values were lower for Portable Network Graphic and Graphics Interchange Format compression formats. CONCLUSION: Image compression with JPEG 2000 at a ratio of 20:1 provided sufficient quality for glaucoma analysis in conjunction with a relatively small image size format, and may prove to be attractive for HRT telemedicine applications. Further clinical studies validating the usefulness of interpreting non-analyzed HRT images are required.
机译:背景与目的:评价未经分析的海德堡视网膜断层扫描(HRT;海德堡工程,海德堡,德国)图像的不同图像压缩格式对眼科医生诊断青光眼的效果。材料与方法:使用9种不同的压缩格式对代表不同疾病水平的HRT拍摄的33幅地形图和反射率图像进行了转换。三名独立的眼科医生遮盖了轮廓线和立体参数,将原始和压缩的HRT图像分类为正常,可疑青光眼或青光眼,并计算了Kappa一致性系数。结果:标记图像文件格式具有最大的文件大小,联合图像专家组(JPEG)2000格式具有最小的大小。对于使用“标记图像文件格式”的所有眼科医生,最高Kappa系数值为1.00。 JPEG格式的Kappa值都在良好一致性到良好一致性的范围内。可移植网络图形和图形交换格式压缩格式的Kappa值较低。结论:以2000:1的比例使用JPEG 2000进行图像压缩可为青光眼分析提供足够的质量,同时具有相对较小的图像尺寸格式,并且可能被证明对HRT远程医疗应用具有吸引力。需要进行进一步的临床研究,以证实解释未分析的HRT图像的有用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号