首页> 外文期刊>Ophthalmic Research: Journal for Research in Experimental and Clinical Ophthalmology >Nonlinear component of the electroretinogram recorded from the posterior pole of normal and highly myopic human eyes.
【24h】

Nonlinear component of the electroretinogram recorded from the posterior pole of normal and highly myopic human eyes.

机译:从正常和高度近视人眼的后极记录的视网膜电图的非线性分量。

获取原文
获取原文并翻译 | 示例
           

摘要

To extract the nonlinear component of the electroretinogram (ERG) from the posterior pole (pp) of the human ocular fundus and to evaluate the possibility of its clinical application, three types of stimulus modes - double-flash, single-flash, and delayed single-flash stimuli - were produced using a conventional electrophysiological system. A large hexagonal element was presented on a CRT monitor, and ppERGs were recorded from 14 normal eyes and 16 eyes of eight highly myopic patients. The nonlinear component of the ppERG was obtained by subtracting the single-flash ERG and delayed single-flash ERG responses from the double flash ERG response. Three peaks were commonly observed in the nonlinear component of ppERG, all of which were significantly depressed in patients with high myopia. ppERGs that can be obtained using a simple algorithm might be useful in clinical applications.
机译:要从人眼底后极(pp)提取视网膜电图(ERG)的非线性成分并评估其临床应用的可能性,可以使用三种刺激模式-两次闪光,一次闪光和延迟单次闪光刺激-使用常规电生理系统产生。在CRT监视器上显示了一个大的六边形元素,并从8位高度近视患者的14只正常眼和16只眼中记录了ppERG。 ppERG的非线性成分是通过从双闪ERG响应中减去单闪ERG和延迟的单闪ERG响应而获得的。通常在ppERG的非线性成分中观察到三个峰,在高度近视患者中所有这些峰均显着降低。可以使用简单算法获得的ppERG在临床应用中可能会有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号