A radiation shielding study against primary and secondary gas bremsstrahlung is carried out for a tungsten collimator/stop, which is one of the components employed in the VESPERS beamline at the Canadian Light Source. The dose and dose rate are obtained by calculating the energy deposition in a water phantom which surrounds the collimator/stop unit. The dose rate behind a vacuum hole of the collimator/stop which leads to the experimental hutch is closely examined. The dose rates are further investigated with the addition of a tungsten shutter that is positioned in front of the collimator/stop. (C) 2007 Elsevier Ltd. All rights reserved.
机译:针对钨准直器/光阑进行了针对一次和二次气体致辐射的辐射屏蔽研究,该准直器/停止器是加拿大光源VESPERS光束线中使用的组件之一。通过计算围绕准直仪/光阑单元的水模中的能量沉积来获得剂量和剂量率。仔细检查准直器/挡块真空孔后面通向实验箱的剂量率。通过在准直器/光阑前面放置钨制百叶窗,可以进一步研究剂量率。 (C)2007 Elsevier Ltd.保留所有权利。