A new Moxon-Rae detector configuration based on Si semiconductor detector was proposed in this paper. Three gamma-ray sources, Cs-137, Co-60, and Na-24, were employed to make actual measurements using the new Moxon-Rae detector. The measured pulse height spectra and detection efficiencies were compared with the EGS4 simulated values. The results revealed that the proposed new configuration is indeed a successful method and specially a useful technique for higher energy gamma-ray measurement. (C) 2002 Elsevier Science Ltd. All rights reserved. [References: 6]
机译:提出了一种基于硅半导体探测器的新型莫克森-雷探测器构造。使用新型的Moxon-Rae检测器,使用了三种伽玛射线源Cs-137,Co-60和Na-24进行了实际测量。将测得的脉冲高度谱和检测效率与EGS4模拟值进行比较。结果表明,提出的新配置确实是一种成功的方法,特别是对于高能伽马射线测量非常有用的技术。 (C)2002 Elsevier ScienceLtd。保留所有权利。 [参考:6]