Diabetic retinopathy can result in impaired photostress recovery time despite normal visual acuity and fundoscopic appearance. The Macular Degeneration Detector (MDD-2) is a novel flash photostress recovery time device. In this study, we examine the repeatability of the MDD-2 in normal and diabetic subjects. METHODS:: One hundred and ninety one (90 women, 101 men) subjects were recruited and divided into 1 of the 3 study groups (normal controls, n = 40; diabetes no retinopathy, n = 98; nonproliferative diabetic retinopathy, n = 53). Photostress recovery time was measured three times in the study eye using the MDD-2, each measurement separated by a 5-minute interval. RESULTS:: Repeated measures analysis of variance revealed no statistically significant learning or fatigue effects on intrameasurement repeatability for any group. Photostress recovery time measures were broadly similar and typically not statistically significantly different between study groups. The coefficient of repeatability reached clinically acceptable levels once the initial photostress recovery time measure, which demonstrated increased variability and latency compared with all subsequent measures, was excluded. CONCLUSION:: The MDD-2 seems to provide repeatable photostress recovery time measurements among naive diabetic subjects. The device does not, however, seem capable of differentiating normal and nonproliferative diabetic eyes, and would not be suitable for inclusion in diabetic retinopathy screening protocol.
机译:尽管正常的视敏度和眼底镜外观,糖尿病性视网膜病可导致光应激恢复时间受损。黄斑变性检测器(MDD-2)是一种新型的闪光光应力恢复时间装置。在这项研究中,我们检查了正常和糖尿病受试者中MDD-2的可重复性。方法:招募了911名(90名女性,101名男性)受试者,将其分为3个研究组中的1个(正常对照组,n = 40;糖尿病无视网膜病变,n = 98;非增生性糖尿病视网膜病变,n = 53)。 )。使用MDD-2在研究眼睛中测量了3次光应力恢复时间,每次测量间隔5分钟。结果:方差的重复测量分析显示,任何组对测量内重复性均无统计学意义的学习或疲劳影响。研究组之间的光应激恢复时间测度大致相似,通常在统计学上没有显着差异。一旦排除了最初的光应激恢复时间量度(与所有后续量度相比,变异性和潜伏期增加),可重复性系数达到临床可接受的水平。结论:MDD-2似乎可以为幼稚的糖尿病受试者提供可重复的光应激恢复时间测量。但是,该设备似乎无法区分正常和非增殖性糖尿病眼,因此不适合纳入糖尿病性视网膜病变筛查方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号