PURPOSE: The purpose of this study was to evaluate the safety and efficacy of 2-port 20-gauge pars plana vitrectomy with a slit-lamp illumination system in different vitreoretinal pathologies.DESIGN: Retrospective, consecutive, interventional case series.METHODS: One hundred and ninety-five consecutive eyes of 195 patients underwent 20-gauge 2-port pars plana vitrectomy with a combination of slit-lamp illumination and a plano-concave contact lens, at the San Paolo Ophthalmology Center, from September 2005 through November 2007.Postoperative visual acuity at baseline and at 1, 3, and 6 months; intraoperative and postoperative complication rate; and surgical time were evaluated.RESULTS: All patients completed 6 months of follow-up.The mean overall visual acuity was 0.74 ± 0.03 (mean ± SD) at baseline, improving to 0.56 ± 0.03 (P < 0.0001), 0.48 ± 0.03 (P < 0.0001), and 0.43 ± 0.03 (P < 0.0001) at 1, 3, and 6 months, respectively.No intraoperative complications occurred.Postoperative complications included retinal detachment in three patients, epiretinal membrane recurrence in three eyes, persistent macular hole in four eyes, and phthisis in one eye.Cataract formation was observed in 25 eyes.The total mean surgical time was 28.3 ± 10.1 minutes.No one had hypotony after the surgical procedure, and no cases of endophthalmitis were observed.Conversion to standard three-port vitrectomy was not necessary in any of the cases.CONCLUSION: Two-port 20-gauge pars plana vitrectomy with slit-lamp illumination is a safe and effective procedure for posterior segment surgeries.
机译:目的:本研究的目的是评估采用裂隙灯照明系统的2端口20口径平视玻璃体玻璃体切除术在不同的玻璃体视网膜病变中的安全性和有效性。设计:回顾性,连续性,介入性病例系列方法:一百例2005年9月至2007年11月,在San Paolo眼科中心对195名患者的95副连续眼睛进行了20线规2孔标准平玻璃体切除术,并结合了裂隙灯照明和平凹隐形眼镜。基线以及1、3和6个月时的视敏度;术中和术后并发症发生率;结果:所有患者均完成了6个月的随访,基线时的平均总视力为0.74±0.03(平均值±SD),分别提高至0.56±0.03(P <0.0001),0.48±0.03( P <0.0001),分别在第1、3和6个月时为0.43±0.03(P <0.0001),没有发生术中并发症。术后并发症包括3例视网膜脱离,3眼视网膜前膜复发,持续性黄斑裂孔。四只眼,一只眼睛有眼睑炎; 25只眼观察到白内障形成,总平均手术时间为28.3±10.1分钟;手术后无人出现肌张力低下;无眼内炎病例;转换为标准三眼结论:在任何情况下都不需要进行玻璃体切除术。结论:采用裂隙灯照明的两口20口径pars平面玻璃体切除术是后段手术的安全有效方法。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号