...
首页> 外文期刊>Radiology >Incidental adrenal lesions: accuracy of characterization with contrast-enhanced washout multidetector CT--10-minute delayed imaging protocol revisited in a large patient cohort.
【24h】

Incidental adrenal lesions: accuracy of characterization with contrast-enhanced washout multidetector CT--10-minute delayed imaging protocol revisited in a large patient cohort.

机译:偶发性肾上腺病变:在大型患者队列中再次使用对比增强冲洗多检测器CT--10-分钟延迟成像方案表征的准确性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To reassess the accuracy of the 10-minute delayed scan to differentiate both lipid-rich and lipid-poor lesions in a large cohort of patients. MATERIALS AND METHODS: This HIPAA-compliant retrospective study had institutional review board approval; the need for informed consent was waived. A multidetector computed tomography (CT) adrenal protocol (unenhanced, dynamic contrast material-enhanced, and 10-minute delayed CT) was used in 314 consecutive patients (201 women, 113 men; mean age, 63.6 years) for the period from January 2006 through February 2009. The mean adrenal attenuation during all three CT phases was measured by two readers, and the relative percentage washout (RPW) and absolute percentage washout (APW) values were calculated. APW and RPW receiver operating characteristic (ROC) analysis was performed to evaluate the strength of the tests. RESULTS: There were 323 adrenal lesions (213 left, 110 right) consisting of 307 adenomas and 16 nonadenomas. The sensitivity, specificity, and accuracy for the RPW test at a washout threshold of 50% were 55.7%, 100%, and 57.9%, respectively; at 40% were 76.9%, 93.7%, and 77.7%; and at 35% were 81.4%, 93.7%, and 82.0%. The sensitivity, specificity, and accuracy for the APW test at a 60% threshold were 52.1%, 93.3%, and 54.0%, respectively; at 55% were 62.5%, 93.3%, and 64.0%; and at 50% were 71.3%, 80.0%, and 71.7%. Areas under the ROC curve were 0.85 (95% confidence interval: 0.75, 0.95) and 0.91 (95% confidence interval: 0.85, 0.97) for the APW and RPW tests, respectively, to detect adenomatous disease. CONCLUSION: The 10-minute delayed adrenal enhancement washout test has reduced sensitivity for the characterization of adrenal adenomas compared with results from prior studies.
机译:目的:为了重新评估10分钟延迟扫描的准确性,以区分大量患者的高脂和低脂病变。材料与方法:符合HIPAA要求的回顾性研究获得了机构审查委员会的批准;无需知情同意。自2006年1月起,连续314例患者(201例女性,113例男性;平均年龄63.6岁)使用了多探测器计算机断层扫描(CT)肾上腺协议(增强,动态对比增强扫描和延迟10分钟的CT)直到2009年2月。由两个读数器测量所有三个CT阶段的平均肾上腺衰减,并计算相对洗脱百分比(RPW)和绝对洗脱百分比(APW)值。进行了APW和RPW接收机工作特性(ROC)分析,以评估测试的强度。结果:共有323个肾上腺病变(左213个,右110个),由307个腺瘤和16个非腺瘤组成。洗脱阈值为50%时RPW测试的灵敏度,特异性和准确性分别为55.7%,100%和57.9%;在40%时分别为76.9%,93.7%和77.7%;在35%时分别为81.4%,93.7%和82.0%。在阈值60%时,APW测试的灵敏度,特异性和准确性分别为52.1%,93.3%和54.0%。在55%时分别为62.5%,93.3%和64.0%;在50%时分别为71.3%,80.0%和71.7%。用于检测腺瘤病的APW和RPW测试的ROC曲线下面积分别为0.85(95%置信区间:0.75、0.95)和0.91(95%置信区间:0.85、0.97)。结论:与先前研究结果相比,延迟10分钟的肾上腺增强洗脱试验降低了对肾上腺腺瘤特征的敏感性。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号