In food industry, biofilms are a source of recalcitrant contaminations, being possible sources of public health problems. The aims of this study were evaluate the disinfectant efficacy of peracetic acid against Pseudomonas aeruginosa biofilms grown on polystyrene surfaces, determining the best method to measuring its disinfecting efficacy. PERA safeReg. has been used as peracetic acid donor into medium. Direct colony-forming units (CFUs) counts together with two assays based in optical density measurement have been tested. Starting from bacterial suspensions (~105), the log10 values obtained were 4.34+or-0.20, 2.60+or-0.77 and 0.00 for 0.4%, 0.8% and 1.61%, PERAsafeReg. concentrations, respectively, showing that this compound achieved the 100% killing efficacy against P. aeruginosa biofilms. Comparative study among the selected tests shows similar results between CFUs counts and spectrophotometry, but there are significant differences between direct counting and McFarland test. At concentration of 1.61%, the correlation factors were 0.8998 and 0.7338 when comparing CFU direct counting with microplate absorbance measurements and McFarland turbidity tests, respectively. These results show that measurement on microplates is an effective tool to evaluate the effectiveness of PERAsafeReg. against P. aeruginosa biofilms, being able to effectively replace the CFUs count in routine tests to determine the sterilization levels on surfaces
机译:在食品工业中,生物膜是顽固性污染物的来源,是公共卫生问题的可能来源。这项研究的目的是评估过氧乙酸对聚苯乙烯表面上生长的铜绿假单胞菌生物膜的消毒效果,从而确定了测量其消毒效果的最佳方法。 PERA safeReg。已被用作培养基中的过氧乙酸供体。已经测试了直接菌落形成单位(CFU)的计数以及基于光密度测量的两种测定。从细菌悬浮液(〜10 5 )开始,获得的log 10 值分别为4.34 + or-0.20、2.60 + or-0.77和0.00,分别为0.4%,0.8%和1.61%,PERAsafeReg。浓度分别表明该化合物对铜绿假单胞菌生物膜具有100%的杀灭功效。选定测试之间的比较研究表明,CFU计数和分光光度法的结果相似,但是直接计数和McFarland测试之间存在显着差异。在浓度为1.61%时,将CFU直接计数与微孔板吸光度测量和McFarland浊度测试进行比较时,相关因子分别为0.8998和0.7338。这些结果表明,在微孔板上进行测量是评估PERAsafeReg有效性的有效工具。对抗铜绿假单胞菌生物膜,能够有效替代常规测试中的CFU计数以确定表面灭菌水平

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号