A sensitive fluorimetric method is presented and discussed for the determination of pentachlorophenol in aqueous solutions. This method is based on the inhibitory effect of pentachlorophenol on the reaction of conventional Fenton [Fe(III) + H2O2] reagent with rhodamine B in the medium of perchloric acid, which results in the fluorescence quenching of rhodamine B. It was further found that the sensitivity for the determination was improved significantly when the molecular ligand EDTA was added. This improved system was therefore presented for the determination of pentachlorophenol. The characteristics of the excitation and emission spectra, optimization of the experimental conditions, the stability of the system and the influence of foreign matter have all been investigated. Under optimal conditions, the linear range for the determination of pentachlorophenol is 12-480 ng/mL with a 3 sigma limit of detection of 0.96 ng/mL. Compared with the conventional Fenton system, the improved system shows obvious advantages in both sensitivity and selectivity. By combination with the pretreatment of samples using ion exchange resins and XDA-1 absorption resin, the improved Fenton method was used for the first time for the determination of pentachlorophenol in synthetic samples and natural water samples, and satisfactory results, in agreement with those of the HPLC method, were achieved. The possible mechanism of the reactions has also been discussed. Copyright (C) 2007 John Wiley & Sons, Ltd.
机译:提出并讨论了一种灵敏的荧光法测定水溶液中的五氯苯酚。该方法是基于五氯苯酚对传统Fenton [Fe(III)+ H2O2]试剂与罗丹明B在高氯酸介质中的反应的抑制作用,导致罗丹明B的荧光猝灭。加入分子配体EDTA后,测定灵敏度大大提高。因此,提出了用于五氯苯酚测定的改进系统。激发和发射光谱的特征,实验条件的优化,系统的稳定性以及异物的影响都已被研究。在最佳条件下,测定五氯苯酚的线性范围为12-480 ng / mL,3σ的检测极限为0.96 ng / mL。与传统的Fenton系统相比,改进后的系统在灵敏度和选择性上都显示出明显的优势。结合离子交换树脂和XDA-1吸收树脂对样品的预处理,首次使用改进的Fenton方法测定合成样品和天然水样品中的五氯苯酚,并获得满意的结果,与实现了HPLC方法。还讨论了反应的可能机理。版权所有(C)2007 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号