首页> 外文期刊>NMR in biomedicine >The time window of MRI of murine atherosclerotic plaques after administration of CB2 receptor targeted micelles: inter-scan variability and relation between plaque signal intensity increase and gadolinium content of inversion recovery prepared versus non-prepared fast spin echo
【24h】

The time window of MRI of murine atherosclerotic plaques after administration of CB2 receptor targeted micelles: inter-scan variability and relation between plaque signal intensity increase and gadolinium content of inversion recovery prepared versus non-prepared fast spin echo

机译:给予CB2受体靶向的胶束后,鼠的动脉粥样硬化斑块MRI的时间窗:扫描前的变异性和斑块信号强度增加与prepared恢复与未制备的快速自旋回声的g含量之间的关系

获取原文
获取原文并翻译 | 示例
           

摘要

Single fast spin echo scans covering limited time frames are mostly used for contrast-enhanced MRI of atherosclerotic plaque biomarkers. Knowledge on inter-scan variability of the normalized enhancement ratio of plaque (NERplaque) and relation between NERplaque and gadolinium content for inversion-recovery fast spin echo is limited. Study aims were: evaluation of (1) timing of MRI after intravenous injection of Cannabinoid-2 receptor (CB2-R) (expressed by human and mouse plaque macrophages) targeted micelles; (2) inter-scan variability of inversion-recovery fast spin echo and fast spin echo; (3) relation between NERplaque and gadolinium content for inversion-recovery fast spin echo and fast spin echo. Inversion-recovery fast spin echo/fast spin echo imaging was performed before and every 15 min up to 48 h after injection of CB2-R targeted or control micelles using several groups of mice measured in an interleaved fashion. NERplaque (determined on inversion-recovery fast spin echo images) remained high (similar to 2) until 48 h after injection of CB2-R targeted micelles, whereas NERplaque decreased after 36 h in the control group. The inter-scan variability and relation between NERplaque and gadolinium (assessed with inductively coupled plasma- mass spectrometry) were compared between inversion-recovery fast spin echo and fast spin echo. Inter-scan variability was higher for inversion-recovery fast spin echo than for fast spin echo. Although gadolinium and NERplaque correlated well for both techniques, the NER of plaque was higher for inversion-recovery fast spin echo than for fast spin echo. In mice injected with CB2-R targeted micelles, NERplaque can be best evaluated at 36-48 h post-injection. Because NERplaque was higher for inversion-recovery fast spin echo than for fast spin echo, but with high inter-scan variability, repeated inversion-recovery fast spin echo imaging and averaging of the obtained NERplaque values is recommended.
机译:覆盖有限时间范围的单次快速自旋回波扫描主要用于动脉粥样硬化斑块生物标记物的对比增强MRI。反转恢复快速自旋回波的标准化斑块增强比(NERplaque)的扫描间变异性以及NERplaque和g含量之间的关系的知识有限。研究目的是:(1)静脉注射大麻素2受体(CB2-R)(由人和小鼠斑块巨噬细胞表达)靶向胶束后的MRI时机; (2)反转恢复快速自旋回波和快速自旋回波的扫描间变异性; (3)NERplaque和g含量之间的关系,用于反转恢复快速自旋回波和快速自旋回波。使用以交错方式测量的几组小鼠,在注射CB2-R靶向胶束或对照胶束之前和之后直至48小时,每15分钟进行一次反转恢复快速自旋回波/快速自旋回波成像。 NERplaque(由反转恢复快速自旋回波图像确定)在注射CB2-R靶向胶束后48小时内一直保持较高(类似于2),而对照组中NERplaque在36 h后下降。在反转恢复快速自旋回波和快速自旋回波之间比较了NERplaque和g之间的扫描间变异性和关系(通过电感耦合等离子体质谱法评估)。反转恢复快速自旋回波的扫描间变异性高于快速自旋回波。尽管g和NERplaque在这两种技术中具有很好的相关性,但反转恢复快速自旋回波的斑块NER高于快速自旋回波。在注射了CB2-R靶向胶束的小鼠中,NERplaque可以在注射后36-48 h进行最佳评估。由于NERplaque用于反转恢复快速自旋回波的频率要高于快速自旋回波,但具有较高的扫描间可变性,因此建议重复进行反转恢复快速自旋回波成像并平均获得的NERplaque值。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号