首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries
【24h】

In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries

机译:体内无聚合物的Biolimus A9洗脱支架与可生物降解的基于聚合物的Biolimus A9洗脱支架和裸金属支架在球囊裸露和辐射的高胆固醇血症兔动脉中的体内比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives: To evaluate the effect of a polymer-free Biolimus A9-eluting stent [BioFreedom? (BF)], compared with that of a biodegradable polymer-based Biolimus A9-eluting stent [BioMatrix Flex? (BMF)] and a bare metal stent (BMS) in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries. Methods: Rabbits were fed with 1% cholesterol diet (n = 14) for 14 days, both iliac arteries were balloon denuded and radiated, and then rabbits were switched to 0.15% cholesterol diet. After 4 weeks, BF (n = 8), BMF (n = 8), and BMS (n = 8) were deployed in denuded and radiated areas. Four weeks later animals were euthanized, arterial segments were processed for morphometry. Results: The neointimal area in vessels implanted with BF stents was significantly less than that seen in vessels implanted with BMS (0.90 mm 2 ± 0.14 vs. 1.29 mm 2 ± 0.23, P 0.01). Percent fibrin and fibrin score were higher with BMF stents compared to BMS (P 0.03 and 0.04) and giant cell number was significantly higher with both BMF and BF stents (P 0.01 for both). Percent endothelialization was significantly higher and % uncovered struts were lower with BMS compared to either BMF or BF stents (P 0.05 for both). Conclusion: This study demonstrates that compared to BMS, BF stents significantly decreased neointimal hyperplasia.
机译:目的:评估无聚合物Biolimus A9洗脱支架的效果[BioFreedom? (BF)]与可生物降解的基于聚合物的Biolimus A9洗脱支架[BioMatrix Flex? (BMF)]和裸露的金属支架(BMS)在球囊中裸露和放射出高胆固醇血症的兔art动脉。方法:给兔子喂食1%胆固醇饮食(n = 14)14天,对两个动脉进行球囊摘除术并放疗,然后换成0.15%胆固醇饮食。 4周后,在裸露和辐射的区域部署了BF(n = 8),BMF(n = 8)和BMS(n = 8)。四周后,对动物实施安乐死,对动脉节段进行形态测定。结果:植入BF支架的血管的新内膜面积明显小于植入BMS的血管(0.90 mm 2±0.14 vs. 1.29 mm 2±0.23,P <0.01)。与BMS相比,BMF支架的纤维蛋白和纤维蛋白分数更高(P <0.03和<0.04),BMF和BF支架的巨细胞数均显着更高(两者均P <0.01)。与BMF或BF支架相比,BMS的内皮化百分比显着更高,未覆盖的支撑百分比更低(两者均P <0.05)。结论:这项研究表明,与BMS相比,BF支架可显着减少新内膜增生。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号