首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >Transcatheter closure of the patent arterial duct using the Flipper coil in a premature infant weighing 1,400 g: a case report.
【24h】

Transcatheter closure of the patent arterial duct using the Flipper coil in a premature infant weighing 1,400 g: a case report.

机译:在体重为1400 g的早产儿中使用Flipper线圈经导管封闭专利动脉导管:一例病例报告。

获取原文
获取原文并翻译 | 示例
       

摘要

A symptomatic 1,400 g premature triplet underwent successful transcatheter coil embolization of patent arterial duct using the umbilical artery. One 3 mm x 3 cm Flipper coil was used with no angiographic residual shunt. To the best of our knowledge, this is one of the smallest preterm infants to undergo this transcatheter procedure.
机译:有症状的1,400 g早产三联体成功通过脐动脉经导管介入了动脉导管未闭。使用一个3 mm x 3 cm的Flipper线圈,无血管造影残留分流。据我们所知,这是接受这种经导管手术的最小的早产儿之一。