Compared with 6F catheters, diagnostic coronary angiographic and ventriculographic images with 4F catheters can be obtained with equivalent results using less radiographic contrast volume. Whether 4F coronary angiography would be superior using a power-assisted, operator-controlled technique compared with manual technique is unknown. To determine whether 4F coronary angiography using operator-controlled power injection (Acist, Minneapolis, MN) was equivalent or superior to the 4F manual technique, 96 unselected patients undergoing transfemoral coronary angiography were randomized to 4F catheter using a power injection or manual technique. Procedural characteristics and angiographic quality scores were analyzed. Comparing the 4F manual with the 4F power-injection technique, coronary angiographic quality scores were equivalent (left coronary artery 4.7 +/- 0.5 vs. 4.7 +/- 0.6, P = 0.99; right coronary artery 4.94 +/- 0.2 vs. 4.88 +/- 0.1, P = 0.21). Left ventriculography scores were lower in 4F Acist with similar contrast volumes. The total study contrast volume was significantly less in the 4F Acist group (119 +/- 35 vs. 149 +/- 49 ml, P = 0.001). Compared with the 4F manual contrast injection technique, diagnostic angiography through 4F catheters with power contrast injection resulted in equivalent coronary angiographic image quality with significantly less radiographic contrast volume.
机译:与6F导管相比,使用4F导管可获得的诊断性冠状动脉造影和心室造影图像具有相同的结果,而射线照相造影剂的体积较小。与手动技术相比,使用动力辅助,操作员控制的技术进行4F冠状动脉造影是否会更好尚不清楚。为了确定使用操作者控制的动力注射(Acist,Minneapolis,MN)进行的4F冠状动脉造影是否等同于或优于4F手动技术,将96例经股动脉冠状动脉造影的未选择患者通过动力注射或手动技术随机分配到4F导管中。程序特征和血管造影质量得分进行了分析。将4F手册与4F动力注入技术进行比较,冠状动脉造影质量得分是相同的(左冠状动脉4.7 +/- 0.5 vs. 4.7 +/- 0.6,P = 0.99;右冠状动脉4.94 +/- 0.2 vs. 4.88 +/- 0.1,P = 0.21)。在4F Acist中,左心室评分较低,造影剂体积相似。 4F Acist组的总研究造影剂体积明显减少(119 +/- 35 vs. 149 +/- 49 ml,P = 0.001)。与4F手动造影剂注射技术相比,通过4F导管进行动力造影剂注射的诊断性血管造影术可产生等效的冠状动脉造影图像质量,而放射照相的造影剂体积则明显更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号