PbWO4 has been selected as the most appropriate scintillator for future calorimeter projects at LHC to detect high energy photons in the multiple GeV range. In spite of the low yield of scintillation light, the applicability in photon and particle detection at energies well below 1 Gev has been studied using electrons between 180 and 855 MeV. The crystals (20x20x150mm(3)) are characterized by the optical quality and the response to low energy gamma-sources using hybrid photo diode tubes. The energy resolution of the electromagnetic shower deposited by electrons in a 3x3 crystal matrix amounts to sigma/E = 2.39%/root E + 0.20% (E given in GeV). The obtained time resolution of sigma less than or equal to 130 ps allows photon/particle discrimination via time-of-flight measurement. [References: 5]
机译:在大型强子对撞机的未来热量计项目中,PbWO4被选为最合适的闪烁体,以检测多个GeV范围内的高能光子。尽管闪烁光的产量低,但已使用180至855 MeV的电子研究了远低于1 Gev的能量在光子和粒子检测中的适用性。晶体(20x20x150mm(3))的特点是光学质量以及使用混合光电二极管管对低能伽马源的响应。电子在3x3晶体矩阵中沉积的电磁辐射的能量分辨率为sigma / E = 2.39%/ root E + 0.20%(E在GeV中给出)。所获得的sigma小于或等于130 ps的时间分辨率允许通过飞行时间测量来区分光子/粒子。 [参考:5]