首页> 外文期刊>Catheterization and cardiovascular interventions: Official journal of the Society for Cardiac Angiography & Interventions >Retrieval of dislodged and disfigured transradially delivered coronary stent: report on a case using forcep and antegrade brachial sheath insertion.
【24h】

Retrieval of dislodged and disfigured transradially delivered coronary stent: report on a case using forcep and antegrade brachial sheath insertion.

机译:取回经椎弓根移位和毁损的冠状动脉支架:报告使用镊子和顺行肱动脉鞘插入术的病例。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We report a case of dislodged and damaged stent during transradial coronary procedure using 6 Fr device, which was successfully retrieved by using a forcep and 8 Fr antegrade brachial sheath. The disfigured and bulky stent can be removed, after their retrieval from the coronary circulation, using a forcep inserted through an 8 Fr brachial artery sheath if the radial artery is deemed too small to accommodate larger sheath.
机译:我们报告了一例在使用6 Fr装置进行的coronary动脉冠状动脉手术过程中支架移位和损坏的情况,该情况已通过使用镊子和8 Fr顺行臂鞘成功治愈。如果认为the动脉太小而无法容纳较大的鞘管,则可以使用通过8 Fr肱动脉鞘管插入的镊子从冠状动脉循环中取出变形后的笨重支架。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号