BACKGROUND AND METHOD: In the measurement of glomerular filtration rate from the plasma clearance of 51Cr ethylenediamine tetraacetic acid by using the slope-intercept method, the first sample is conventionally taken at 2 h, the time by which it is generally assumed that the clearance curve has reached a single exponential. We examined this assumption by comparing the slopes, alpha 12 and alpha 23, based, respectively, on samples at 2 and 3 h, and at 3 and 4 h. RESULTS: In 421 patient studies in whom the first sample was taken between 110 and 130 min after injection, the mean ratio, alpha 12/alpha 23, was 1.101 (SEM 0.011) which is significantly higher than unity (P0.001). The relationship between alpha 12/alpha 23 and the slope, alpha 13 (which is a measure of filtration function already indexed for body size) based on all three samples was negative. By modelling the relationship between mixing time and alpha 13 it was shown that this relationship suggests delayed mixing of the indicator throughout its distribution volume and is inconsistent with irreversible binding of indicator to plasma protein. A significant positive association was observed between alpha 12/alpha 23 and age, but this is largely explained by a generally poorer filtration function in the older age group since low levels of alpha 13 theoretically predict a longer mixing time. In 188 patient studies in whom the first sample was taken more than 130 min after injection, the mean ratio, alpha 12/alpha 23, was 1.055 (SEM 0.017) which is still significantly higher than unity (P0.005) but significantly less than the ratio based on studies in which the first sample was taken at 110-130 min (P<0.02). The ratio alpha 12/alpha 23 still showed a significant relation (positive) with age but not with filtration function. CONCLUSION: This error in the estimation of glomerular filtration rate to which delayed mixing leads will make its greatest impact when using the simplified slope-only technique, but can be minimized by delaying the first blood sample.
机译:背景与方法:在采用斜截方法从51Cr乙二胺四乙酸的血浆清除率测定肾小球滤过率时,通常在2 h采集第一个样品,通常认为该时间是清除率曲线已达到一个指数。我们通过比较分别基于2 h和3 h以及3 h和4 h的样本的斜率alpha 12和alpha 23来检验此假设。结果:在421名患者研究中,他们在注射后110至130分钟之间采集了第一份样品,其平均比率α12 /α23为1.101(SEM 0.011),显着高于单一性(P 0.001)。基于所有三个样本的alpha 12 / alpha 23与斜率alpha 13(这是已经针对人体大小建立的过滤功能的度量)之间的关系为负。通过对混合时间和α13之间的关系进行建模,表明该关系表明指示剂在其整个分布体积中的混合延迟,并且与指示剂与血浆蛋白的不可逆结合相矛盾。观察到α12 /α23与年龄之间存在显着的正相关性,但这在很大程度上可以解释为老年人群中的过滤功能普遍较差,因为理论上较低的α13水平可预测更长的混合时间。在188个患者研究中,注射后130分钟以上采集了第一份样品,平均比率alpha 12 / alpha 23为1.055(SEM 0.017),仍显着高于单一性(P 0.005),但显着低于比基于在110-130分钟时采集第一个样品的研究的比率(P <0.02)。比例α12 /α23仍与年龄呈显着正相关,与过滤功能无关。结论:在使用简化的仅斜率技术时,延迟混合导致的肾小球滤过率估计中的这一误差将产生最大影响,但可以通过延迟第一个血液样本将其最小化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号