首页> 外文期刊>Nuclear Medicine Communications >Efficiency comparison between 99m Tc-tetrofosmin and 99m Tc-sestamibi myocardial perfusion studies.
【24h】

Efficiency comparison between 99m Tc-tetrofosmin and 99m Tc-sestamibi myocardial perfusion studies.

机译:99m Tc-trofosmin和99m Tc-司他他比心肌灌注研究的效率比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

SUMMARY: The purpose of this investigation was to compare the efficiency of two different imaging protocols using two different clinically available 99mTc labelled myocardial perfusion tracers. One thousand one hundred and thirty-four imaging studies were performed prospectively, using either 99mTc-tetrofosmin or 99mTc-sestamibi, alternating the use of each tracer for a total period of 8 months. 99mTc-tetrofosmin rest studies were performed with injections of 259MBq-370MBq and imaging 30min later. Exercise studies were performed with injections of 777MBq-1.11GBq and imaging 20min later. 99mTc-sestamibi studies used doses similar to those in the 99mTc-tetrofosmin studies. Imaging followed a standard procedure, at 60min after rest injection, and 30min after exercise. For patients undergoing pharmacological stress testing99mTc-sestamibi was imaged 45min after injection and 99mTc-tetrofosmin was imaged 30min after injection. Variables analysed were (1) injection-to-imaging time for the procedure, and (2) the number of repeated scans because of extra cardiac activity. The completion time for the rest study was significantly shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (47.7+/-21.7min vs 74.3+/-25.8min P<0.0001). Likewise, the total study time was shorter for 99mTc-tetrofosmin compared to 99mTc-sestamibi (90+/-32.7min vs 124+/-37min, P<0.0001). More importantly, the number of repeated scans was higher with 99mTc-sestamibi compared to 99mTc-tetrofosmin, 21.4% vs 10%, P=0.001 for rest studies and 19.7% vs 7.9% P=0.1 for rest and stress. It was concluded that, using a same day rest/stress protocol, 99mTc-tetrofosmin provided higher patient throughput with fewer repeat scans. These factors may be considered for efficiency improvement in nuclear cardiology laboratories using 99mTc perfusion tracers.
机译:摘要:这项研究的目的是比较使用两种不同的临床上可用的99mTc标记的心肌灌注示踪剂的两种不同的成像方案的效率。前瞻性地使用99mTc-四氟膦或99mTc-西司他比进行了104项成像研究,交替使用每种示踪剂共8个月。注射259MBq-370MBq进行99mTc-四磷磷灵静息研究,并在30分钟后成像。运动研究通过注射777MBq-1.11GBq进行,并在20分钟后成像。 99mTc-sestamibi研究使用的剂量与99mTc-tetrofosmin研究相似。静注后60分钟和运动后30分钟,按照标准程序进行成像。对于接受药理学压力测试的患者,注射后45分钟对99mTc-司他米比成像,注射后30min对99mTc-替曲磷进行成像。分析的变量是(1)该过程的注射到成像时间,以及(2)由于额外的心脏活动而重复扫描的次数。其余研究的完成时间与99mTc-sestamibi相比,99mTc-替曲磷明显缩短(47.7 +/- 21.7min与74.3 +/- 25.8min,P <0.0001)。同样,与99mTc-西他米比相比,99mTc-替曲磷的总研究时间更短(90 +/- 32.7min与124 +/- 37min,P <0.0001)。更重要的是,与99mTc-tetrofosmin相比,使用99mTc-西他米比的重复扫描次数更高,分别为21.4%和10%,对于静息研究,P = 0.001;对于静息和压力,分别为19.7%和7.9%,P = 0.1。结论是,使用同一天的休息/紧张方案,99mTc-tetrofosmin可提供更高的患者通量,重复扫描次数更少。在使用99mTc灌注示踪剂的核心脏病学实验室中,可以考虑这些因素来提高效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号