SPECT/CT bone imaging after hip resurfacing arthroplasty: is it feasible to use CT attenuation correction in the presence of metal implants?

机译:髋关节置换术后的SPECT / CT骨成像:在存在金属植入物的情况下使用CT衰减校正是否可行?

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: In hip resurfacing arthroplasty a metal implant (prosthesis) is used to resurface the patient's native femoral head. The assessment of bone function around the implant is important in evaluating any subsequent complications. The use of bone single photon emission computed tomography/computed tomography (SPECT/CT) imaging may enhance this evaluation. OBJECTIVES: The primary objective of this study was to ascertain whether SPECT/CT imaging is feasible in the presence of the metal implant. A secondary objective was to deduce the impact attenuation correction has on the detected counts originating from bone covered by the metal implant. METHODS: A phantom was constructed to allow assessment of counts obtained from a point source (PS) imaged in the vicinity of a hip resurfacing implant. Three implant cup sizes (4, 8 and 10) were assessed and images acquired with a PS positioned adjacent to the implant pin and under the cup. Multiple acquisitions were undertaken both with and without surrounding soft tissue equivalent material. The images were analysed with and without attenuation correction and the recovered counts compared with that ofa PS imaged in free space (control). RESULTS: Attenuation-corrected counts did not vary significantly with cup size (P=0.427), PS position (P=0.999), presence of soft tissue equivalent material (P=0.193) or a combination of PS position and soft tissue(P=0.193). The attenuation-corrected counts recovered from a PS (soft tissue equivalent material present) showed an overestimation, compared with the control, both when positioned adjacent to the pin and under the cup; mean 8% (4-16%) and 4% (1-6%), respectively. CONCLUSION: The results of the study suggest that the application of the attenuation correction technique is applicable to bone SPECT/CT images of the femoral head-neck junction acquired in the presence of a hip resurfacing implant.
机译:背景:在髋关节表面置换术中,金属植入物(假体)用于使患者的股骨头自然复新。评估植入物周围的骨功能对于评估任何后续并发症很重要。骨单光子发射计算机断层扫描/计算机断层扫描(SPECT / CT)成像的使用可以增强此评估。目的:本研究的主要目的是确定在金属植入物的存在下SPECT / CT成像是否可行。第二个目的是推论对衰减计数的校正对源自金属植入物覆盖的骨头的检测计数的影响。方法:构建体模以评估从髋关节表面置换植入物附近成像的点源(PS)获得的计数。评估了三种植入物杯大小(4、8和10),并使用与植入物针相邻且位于杯下方的PS来获取图像。在有或没有周围软组织等效材料的情况下均进行了多次采集。在有和没有衰减校正的情况下对图像进行了分析,并将恢复的计数与在自由空间(对照)中成像的PS进行比较。结果:衰减校正的计数在杯尺寸(P = 0.427),PS位置(P = 0.999),存在软组织等效材料(P = 0.193)或PS位置与软组织的组合(P = 0.193)。从PS(存在的软组织当量材料)中回收的经过衰减校正的计数与对照相比,无论是定位在靠近销子还是在杯下方,都显示出高估。平均分别为8%(4-16%)和4%(1-6%)。结论:研究结果表明,衰减校正技术的应用适用于在髋关节表面置换植入物的存在下获得的股骨头-颈部交界处的骨SPECT / CT图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号