AIM: To develop a strategy for checking the reliability of slope intercept measurement of glomerular filtration rate (GFR). METHODS: Six blood samples, obtained bilaterally 20-240 min after the injection of Cr-ethylenediaminetetraacetic acid (EDTA) and iohexol into opposite arms, were assayed for indicator injected contralaterally. GFR6iohexol, the reference value, was measured for all six samples and GFR3EDTA (slope-intercept) for the last three samples (per 1.73 m). GFR was measured from the half-time [GFR/extracellular fluid volume (ECV)3EDTA], for the single samples at 2-4 h (Christensen-Groth; GFR1) and for creatinine [estimated GFR (eGFR)]. RESULTS: In six of the 97 studies, the correlation coefficient (r) of the fit to the last three sample points was less than 0.99. In the remaining 91 studies, GFR3EDTA disagreed with GFR/ECVEDTA by more than 15% in 19 studies (group A) and by less than 15% in 72 studies (group B). GFR3EDTA disagreed with GFR6iohexol by 12.6% in group A but only by 6.3% in group B (P<0.001). No such discrimination was displayed by eGFR. Although GFR3EDTA was within 15%of GFR6iohexol in 14 group A studies, eGFR was within 15% of GFR3EDTA in only eight studies and disagreed by more than 15% in six studies. Conversely, in the five of the 19 studies in which GFR3EDTA disagreed with GFR6iohexol by more than 15%, the agreement between eGFR and GFR3EDTA was less than 15% in two studies and more than 15% in three studies. GFR3EDTA was within 15% of GFR/ECV3EDTA in all six studies in which r was less than 0.99, and GFR3EDTA disagreed with GFR6iohexol by less than 15%. Confidence in GFR3EDTA was not improved by GFR1 or eGFR. CONCLUSION: Slope intercept GFR is reliable if within 15% of GFR/ECV3. Estimated GFR was ineffective as a second checkpoint. GFR1 did not help when the fit was poor.
机译:目的:制定一种检查肾小球滤过率(GFR)的斜率截取测量的可靠性的策略。方法:将六对血液样本从对侧注射Cr-乙二胺四乙酸(EDTA)和碘海醇后分别在20-240分钟的时间进行双侧检测,以测定指标。测量所有六个样品的参考值GFR6iohexol,最后三个样品(每1.73 m)测量GFR3EDTA(斜率截距)。测量半衰期的GFR [GFR /细胞外液体积(ECV)3EDTA],2-4小时的单个样品(Christensen-Groth; GFR1)和肌酐[估计的GFR(eGFR)]。结果:在97个研究中的6个研究中,与最后三个样本点的拟合的相关系数(r)小于0.99。在其余的91项研究中,GFR3EDTA与GFR / ECVEDTA的差异在19项研究(A组)中超过15%,而在72项研究(B组)中不足15%。 GFR3EDTA与GFR6iohexol在A组中的差异为12.6%,但在B组中的差异仅为6.3%(P <0.001)。 eGFR没有显示出这种歧视。尽管在14个A组研究中GFR3EDTA占GFR6iohexol的15%以内,但仅8项研究中eGFR处于GFR3EDTA的15%以内,而在6项研究中eGFR的差异超过15%。相反,在19项研究中的5项中,GFR3EDTA与GFR6iohexol的差异超过15%,其中两项研究中eGFR和GFR3EDTA之间的一致性小于15%,而三项研究中eGFR与GFR3EDTA的一致性超过15%。在所有r均小于0.99的六项研究中,GFR3EDTA均在GFR / ECV3EDTA的15%以内,而GFR3EDTA与GFR6iohexol的差异小于15%。 GFR1或eGFR并未提高对GFR3EDTA的信心。结论:如果GFR / ECV3的15%以内,则斜率截距GFR是可靠的。估计的GFR作为第二检查站无效。当适合性较差时,GFR1没有帮助。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号