Repeatability of left ventricular ejection fraction and volume measurement for 99mTc-tetrofosmin gated single photon emission computed tomography (SPECT).

机译:左心室射血分数的重复性和99mTc-四氧磷门控单光子发射计算机断层扫描(SPECT)的体积测量。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: This study was carried out to assess the repeatability of left ventricular ejection fraction (EF) and volume values obtained using Cedars-Sinai quantitative gated single photon emission computed tomography (SPECT) (QGS) software and relatively low doses of 400-600 MBq of 99mTc-tetrofosmin. METHODS: Repeatability was assessed in a group of 75 patients, with both normal and reduced EF, who underwent repeat 99mTc-tetrofosmin gated SPECT studies and showed no clinical change in cardiac status. Gated SPECT data were acquired 1 h after injection at rest of 400-600 MBq of 99mTc-tetrofosmin. The standard patient dose was 400 MBq; however, some patients with a weight of >90 kg were given increased doses up to a maximum of 600 MBq. RESULTS: There was good correlation of EF and volumes between the first and repeat measurements, and no significant difference between the mean EF and volumes for both the initial and repeat measurements. Background-corrected counts in the left ventricle were calculated and patients were divided into two groups: one with low counts and one with high counts. The mean difference in EF between the first and repeat measurements was significantly higher for patients in the low count group compared with those in the high count group, but there was no significant change in volume. Similarly, the mean sequential difference in EF was significantly higher for patients with normal EF, but there was no significant difference in volume. CONCLUSIONS: We have demonstrated that EF measured using 99mTc-tetrofosmin gated SPECT is repeatable, particularly for patients with low EF, provided that adequate left ventricular counts are obtained. This will require doses greater than 400 MBq in larger patients. Ventricular volumes calculated using QGS may not be sufficiently repeatable for clinical use.
机译:目的:本研究旨在评估使用Cedars-Sinai定量门控单光子发射计算机断层扫描(SPECT)(QGS)软件和相对低剂量的400-600 MBq所获得的左心室射血分数(EF)和体积值的可重复性99mTc-四磷灵方法:对75名EF正常和降低的患者进行了重复性评估,这些患者均进行了99mTc-tetrofosmin门控的SPECT重复研究,但未显示心脏状况的临床改变。注射后1 h,在剩余的400-600 MBq的99mTc-四氧磷中获得门控SPECT数据。患者的标准剂量为400 MBq。但是,某些体重> 90 kg的患者可以增加剂量,最高可达到600 MBq。结果:首次测量和重复测量之间的EF和体积具有良好的相关性,并且对于初始测量和重复测量,平均EF和体积之间没有显着差异。计算左心室的背景校正计数,并将患者分为两组:一组低计数,另一组高计数。与高计数组相比,低计数组患者首次测量和重复测量之间的EF平均差异显着更高,但体积没有明显变化。同样,正常EF患者的EF平均顺序差异显着更高,但体积没有显着差异。结论:我们已经证明,使用99mTc-四氟膦门控SPECT测量的EF是可重复的,特别是对于EF低的患者,只要获得足够的左心室计数即可。对于较大的患者,这将需要大于400 MBq的剂量。使用QGS计算的心室容积可能无法充分重复用于临床。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号