首页> 外文期刊>Nuclear Medicine Communications >SPECT imaging with (123I)-beta-CIT in Parkinsonism: comparison of SPECT images obtained by a single-headed and a three-headed gamma camera.
【24h】

SPECT imaging with (123I)-beta-CIT in Parkinsonism: comparison of SPECT images obtained by a single-headed and a three-headed gamma camera.

机译:用(123I)-CIT在帕金森病中进行SPECT成像:单头和三头伽马相机获得的SPECT图像比较。

获取原文
获取原文并翻译 | 示例
           

摘要

Single photon emission computed tomography (SPECT) imaging of dopamine transporters by using the cocaine derivative [123I]-(1R)-2-beta-carbomethoxy-3-beta-(4-iodophenyl)-tropane ([123I]-beta-CIT) has been shown to be useful in patients with Parkinsonism. The aim of this study was to compare beta-CIT imaging with single-headed (SHS) and three-headed gamma camera systems (THS). In 17 patients with Parkinsonism, SPECT imaging with an SHS and a THS was performed 24 h after injection of 180 MBq of [123I]-beta-CIT. The SPECT studies were evaluated by visual assessment of the caudate nucleus (CN) and the putamen (PT) and the calculation of the striatal/cerebellar (S/C) ratios (with additional comparison to clinical symptoms measured by the Unified Parkinson's Disease Rating Scale (UPDRS)). The S/C ratios measured by the SHS and THS showed highly significant correlation (two-tailed P < 0.01) with Spearman correlation coefficients (SCCs) of 0.864 for the right side, 0.676 for the left side, and 0.761 for both sides. By the SHS, a sufficient visual differentiation between the CN and the PT could not be achieved. A significantly better distinction could be achieved by using the THS (Wilcoxon P<0.05). The S/C ratios of the THS only showed a significant (P < 0.05) SCC of -0.514 comparing to the UPDRS. Pathological alterations in the beta-CIT uptake pattern could be identified by using the SHS, but a significantly better differentiation of CN and the PT was possible by using the THS. The significant correlation of the S/C ratios measured by THS only emphasizes the value of THS in beta-CIT imaging.
机译:多巴胺转运蛋白的单光子发射计算机断层扫描(SPECT)成像,使用可卡因衍生物[123I]-(1R)-2-β-羰甲氧基-3-β-(4-碘苯基)-托烷([123I]-β-CIT已显示)对帕金森氏症患者有用。这项研究的目的是将beta-CIT成像与单头(SHS)和三头伽马相机系统(THS)进行比较。在17例帕金森病患者中,注射180 MBq的[123I]-β-CIT后24 h用SHS和THS进行SPECT成像。通过视觉评估尾状核(CN)和壳状核(PT)以及计算纹状体/小脑(S / C)比(通过统一帕金森氏病评分量表对临床症状进行比较)来评估SPECT研究(UPDRS))。 SHS和THS测得的S / C比具有高度显着的相关性(两尾P <0.01),其Spearman相关系数(SCC)的右侧为0.864,左侧为0.676,两侧均为0.761。通过SHS,无法在CN和PT之间实现足够的视觉区分。使用THS可以实现更好的区分(Wilcoxon P <0.05)。与UPDRS相比,THS的S / C比仅显示出-0.514的显着(P <0.05)SCC。使用SHS可以确定β-CIT摄取模式的病理改变,但是使用THS可以显着更好地区分CN和PT。通过THS测量的S / C比的显着相关性仅强调了THS在beta-CIT成像中的价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号