...
首页> 外文期刊>Neurosurgery >Localization of cerebrospinal fluid leaks by gadolinium-enhanced magnetic resonance cisternography: a 5-year single-center experience.
【24h】

Localization of cerebrospinal fluid leaks by gadolinium-enhanced magnetic resonance cisternography: a 5-year single-center experience.

机译:g增强磁共振水显影对脑脊液漏的定位:5年的单中心经验。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Intrathecal gadolinium (Gd)-enhanced magnetic resonance (MR) cisternography is a newly introduced imaging method. Two main objectives of this study were to investigate the sensitivity of Gd-enhanced MR cisternography for presurgical localization of cerebrospinal fluid (CSF) leaks in patients with CSF rhinorrhea and to study the potential long-term adverse effects of intrathecal Gd application. METHODS: Fifty-one patients (19 women; mean age, 36.2 yr) with CSF rhinorrhea were included in the study. A total of 0.5 ml of Gd was injected into the lumbar subarachnoid space. T1-weighted MR cisternographic images were obtained to detect CSF leakage. The patient's neurological states and vital signs were recorded for the first 24 hours after the procedure. Neurological evaluations were repeated 1, 3, and 12 months after the procedure. The patients were followed for at least 3 years with annual neurological examinations. RESULTS: Gd-enhanced MR cisternography demonstrated CSF leaks in 43 of the 51 patients. The sensitivity of Gd-enhanced MR cisternography for localization of CSF leaks was 84%. Forty-four patients underwent surgery to repair dural tears. Surgical findings confirmed the results of Gd-enhanced cisternography in 43 of the 44 patients who underwent surgery (98%). Eight patients with negative Gd-enhanced MR cisternography had no active rhinorrhea at the time of procedure, and seven of them did not need surgery. None of the patients developed an acute adverse reaction that could be attributed to the procedure. None of the patients developed any neurological symptoms or signs caused by intrathecal Gd injection during a mean follow-up period of 4.12 years. CONCLUSION: Gd-enhanced MR cisternography is a sensitive and safe imaging method for detection of CSF leaks in patients with rhinorrhea.
机译:目的:鞘内g(Gd)增强磁共振(MR)池造影是一种新引入的成像方法。这项研究的两个主要目的是研究Gd增强的MR造影对CSF鼻漏患者脑脊液(CSF)泄漏的术前定位的敏感性,并研究鞘内施用Gd的潜在长期不良影响。方法:51例脑脊液鼻漏患者(19例女性,平均年龄36.2岁)被纳入研究。将总计0.5 ml的Gd注入腰椎蛛网膜下腔。获得T1加权MR脑电图图像以检测CSF渗漏。手术后的最初24小时记录患者的神经系统状态和生命体征。手术后1、3和12个月重复进行神经学评估。每年对患者进行至少3年的神经系统检查。结果:51例患者中43例经Gd增强MR水显影证实脑脊液漏出。 Gd增强的MR造影对CSF漏定位的敏感性为84%。四十四名患者接受了手术以修复硬脑膜撕裂。手术结果证实了接受手术的44例患者中有43例(98%)接受了Gd增强水槽造影的结果。八名Gd增强MR造影阴性的患者在手术时没有活动性鼻漏,其中七名患者不需要手术。没有患者出现可归因于该程序的急性不良反应。在平均随访期4.12年中,没有患者因鞘内注射Gd引起任何神经系统症状或体征。结论:Gd增强MR水肿成像是一种检测鼻漏患者脑脊液漏的灵敏,安全的影像学方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号