首页> 外文期刊>Materials Science >AUTOCLAVE STUDIES OF THE DURABILITY OF SPECIMENS SIMULATING PIPE-COLLECTOR JOINTS IN STEAM GENERATORS OF NUCLEAR POWER PLANTS
【24h】

AUTOCLAVE STUDIES OF THE DURABILITY OF SPECIMENS SIMULATING PIPE-COLLECTOR JOINTS IN STEAM GENERATORS OF NUCLEAR POWER PLANTS

机译:核电厂蒸汽发生器中模拟管道-集热管接头的试样的耐久性的耐压研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We performed studies of welded-pressed (by explosion) joints of pipes made of 08Kh18N10T and 08Kh14MF steels with nozzles made of 10GN2MFA steel in order to simulate the operation of PGV-1000 steam generators. We established that the fatigue limit based on 1 centre dot 10~5 cycles is greater for the joints of pipes made of 08Kh14MF steel in tests in air. On the autoclave tests in reactor boron-treated water in the primary contour of a nuclear power plant at a temperature of 350 deg C, the endurance of the joints of pipes made of 08Kh14MF steel was 39 percent less that that for the joints made of 08Kh18N10T steel. All specimens failed at the lower ends of joints that were in the water phase of the working medium rather than in the steam one, which corresponds to the service conditions of the output "cold" collector of a steam generator. We concluded that cracks are initiated due to fretting corrosion and grow by the mechanism of corrosion-cyclic cracking of the steels of pipes.
机译:为了模拟PGV-1000蒸汽发生器的运行,我们对由08Kh18N10T和08Kh14MF钢制成的管道进行焊接加压(爆炸)接头和由10GN2MFA钢制成的喷嘴进行了研究。我们确定,在空气测试中,由08Kh14MF钢制成的管接头在1个中心点10〜5个循环的基础上的疲劳极限更大。在温度为350摄氏度的核电站主轮廓中的反应堆经硼处理的水中进行高压灭菌试验时,由08Kh14MF钢制成的管接头的耐力比由08Kh18N10T制成的接头的耐力低39%钢。所有标本都在工作介质水相而不是蒸汽相的接头下端失效,这与蒸汽发生器的输出“冷”收集器的使用条件相对应。我们得出的结论是,裂纹是由于微动腐蚀引起的,并通过管道钢的腐蚀循环裂纹机理而扩展。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号