首页> 外文期刊>Advances in modelling and analysis, C. Systems analysis, control and design, simulation, CAD >A simulation study of the regulation of a micro-hydroelectric power plant
【24h】

A simulation study of the regulation of a micro-hydroelectric power plant

机译:微型水力发电厂的调节模拟研究

获取原文

摘要

This article studies, in simulation, the mixed and downstream regulation of an isolated micro hydroelectric power plant (MHPP). A model of the MHPP was developed with simulink based on the work in reference l. The model is used to evaluate the performances of the upstream regulation with PID compensator and anti wind up system. Then, we compared performances obtained with those of the mixed regulation. The results of simulation showed that at the time of an important load variation, the regulation by a simple PID didn't eliminate the possibility of runaway of the turbine. With a mixed compensator, the response of the system was extensively better and became insensitive to load variations.
机译:本文在仿真中研究了孤立微型水力发电厂(MHPP)的混合和下游调节。基于参考文献[l]的工作,使用simulink开发了MHPP模型。该模型用于评估PID补偿器和防缠绕系统的上游调节性能。然后,我们将获得的性能与混合调节的性能进行了比较。仿真结果表明,在发生重要负载变化时,简单的PID调节并不能消除涡轮机失控的可能性。使用混合补偿器时,系统的响应要好得多,并且对负载变化不敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号