A novel mechanical thrombectomy device for retrieval of intravascular thrombus.

机译:一种新颖的机械血栓切除术装置,用于血管内血栓的取出。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. MATERIALS AND METHODS: A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. RESULTS: Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. CONCLUSIONS: The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.
机译:目的:血栓和栓塞性血管闭塞是发病率和死亡率的主要原因。当前可用的血栓切除术装置具有局限性,包括难以去除有组织的血栓和具有远端栓塞的血块破碎。在临床前猪模型中测试了一种新颖的机械血栓切除术装置(MTD),该装置旨在去除硬性血栓和软性血栓,而不会损伤血管,评估了疗效,安全性和易用性。材料与方法:14头猪中共有26支血管接受了MTD机械血栓切除术。血栓切除术是在9个股浅动脉,8个锁骨下动脉,5个锁骨下动脉,胸廓外侧动脉或颈椎干的主要分支以及4个颈外动脉中进行的。将亚急性组织化的富含纤维蛋白的血栓注射到产生血管闭塞的动脉中。然后将MTD用于血栓切除术以恢复通畅和血流。结果:仅通过一次MTD,即可从26支血管中的24支血管中获得完整的血栓,从而使21支血管完全通畅,4支血管部分通畅。在采用早期设计的8例病例中,栓塞材料在从通路鞘管抽出的过程中破碎了。在采用早期设计的4种程序中,MTD无法完全部署且栓塞未被完全捕获。没有发生手术中并发症或血管损伤。结论:目前的先导研究证明了新型MTD的基本安全性和有效性,其设计属性适合于检索完整的急性和有组织的慢性血栓。该设备具有潜在的颅内和外周功能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号