首页> 外文期刊>Cardiovascular engineering >Pulse Wave Velocity and Digital Volume Pulse as Indirect Estimators of Blood Pressure: Pilot Study on Healthy Volunteers
【24h】

Pulse Wave Velocity and Digital Volume Pulse as Indirect Estimators of Blood Pressure: Pilot Study on Healthy Volunteers

机译:脉搏波速度和数字量脉冲作为血压的间接估算器:健康志愿者的初步研究

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of the study was to asses the potential use of pulse wave velocity (PWV) and digital volume pulse (DVP) as estimators of systolic (SBP) and diastolic (DPB) blood pressure. Single and multiple correlation studies were conducted, including biometric parameters and risk factors. Brachial-ankle PWV (baPWV) and DVP signals were obtained from a Pulse Trace PWV and Pulse Trace PCA (pulse contour analysis), respectively. The DVP (obtained by photoplethysmography), allowed stiffness (SI) and reflection indexes (RI) to be derived. The first study on 47 healthy volunteers showed that both SBP and DPB correlated significantly both with baPWV and SI. Multiple regression models of the baPWV and the waist-to-hip ratio (WHR) allowed SBP and DBP to be modeled with r = 0.838 and r - 0.673, respectively. SI results also employed WHR and modeled SBP and DBP with r = 0.852 and r = 0.663, respectively. RI did not correlate either with SBP or DBP. In order to avoid the use of ultrasound techniques to measure PWV, we then developed a custom-built system to measure PWV by photoplethysmography and validated it against the Pulse Trace. With the same equipment we conducted a second pilot study with ten healthy volunteers. The best SBP multiple regression model for SBP achieved r = 0.997 by considering the heart-finger PWV (hfPWV measured between R-wave and index finger), WHR and heart rate. Only WHR was significant in the DBP model. Our findings suggest that the hfPWV photoplethysmography signal could be a reliable estimator of approximate SBP and could be used, for example, to monitor cardiac patients during physical exercise sessions in cardiac rehabilitation.
机译:这项研究的目的是评估脉搏波速度(PWV)和数字量脉搏(DVP)作为收缩压(SBP)和舒张压(DPB)血压估计的潜在用途。进行了单项和多项相关性研究,包括生物特征参数和危险因素。臂踝PWV(baPWV)和DVP信号分别从Pulse Trace PWV和Pulse Trace PCA(脉冲轮廓分析)获得。 DVP(通过光电容积描记术获得),允许导出刚度(SI)和反射指数(RI)。对47位健康志愿者的第一项研究表明,SBP和DPB均与baPWV和SI均显着相关。 baPWV和腰臀比(WHR)的多元回归模型允许分别用r = 0.838和r-0.673来建模SBP和DBP。 SI结果还使用了WHR并建模了SBP和DBP,分别为r = 0.852和r = 0.663。 RI与SBP或DBP均不相关。为了避免使用超声技术来测量PWV,我们随后开发了定制系统以通过光电容积描记法测量PWV,并针对Pulse Trace对它进行了验证。使用相同的设备,我们与十名健康志愿者进行了第二次试点研究。通过考虑心指PWV(在R波和食指之间测量的hfPWV),WHR和心率,SBP的最佳SBP多元回归模型达到r = 0.997。在DBP模型中,只有WHR才有意义。我们的发现表明,hfPWV光电容积描记术信号可能是近似SBP的可靠估算器,并且可以用于例如在心脏康复期间进行体育锻炼期间监测心脏病患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号