The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally, and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.
机译:这项研究的目的是研究肾上动脉支架移植治疗的腹主动脉瘤(AAAs)患者支架支杆(金属丝)对肾动脉的血流动力学影响。选择了两名在多层肾上膜支架置入术前后进行多层CT血管造影的AAA样本患者纳入研究。从多层CT数据集生成了八个专注于肾动脉的近肾模型。在分段主动脉模型中模拟了穿过肾动脉口的支架线的四种类型的配置:单根线在中心交叉,单根线在外围交叉,V形线在中心交叉以及多根线在外围交叉。使用双向流体结构相互作用分析,比较并比较了支架植入前后肾动脉的血流模式,流速,壁压力和壁切应力。模拟直径为0.4、1.0和2.0 mm的支架线厚度,并在不同的心动周期进行血流动力学分析。支架线对肾脏血流的干扰主要取决于支架线的粗细和穿过肾脏口的支架线的构型类型。当支架线的厚度增加到1.0和2.0 mm时,大多数情况下流速降低20-30%。在这四种类型的配置中,单根导线在中心交叉会导致流速的最大降低,在三种不同的导线厚度中,流速的降低范围从21%到28.9%。壁剪应力还取决于导线的厚度,当导线的厚度达到1.0和2.0 mm时,剪应力显着降低。综上所述,我们的初步研究表明,肾上支架血管对AAA肾上支架植入物治疗的血流动力学效应取决于肾上支架金属丝的厚度。我们研究中的研究结果对于肾上支架置入术治疗的患者的随访非常有用,以确保肾上固定的长期安全性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号