首页> 外文期刊>Cardiovascular and Interventional Radiology: A Journal of Imaging in Diagnosis and Treatment >First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.
【24h】

First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

机译:首次在猪中使用基于聚醚醚酮的磁共振成像兼容导丝进行磁共振成像引导的主动脉支架置入和腔静脉滤器放置:概念验证。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
机译:这项研究的目的是证明在磁共振成像(MRI)指导下仅使用基于聚醚醚酮(PEEK)的MRI兼容导丝进行经皮腔内主动脉支架置入术和腔静脉滤器置入术的可行性。在3头家猪中进行了经皮腔内主动脉支架置入术和静脉滤器置入术。在MRI指导下在开孔1.5-T扫描仪中进行操作。所施加的0.035英寸导丝具有PEEK芯线,该芯线由纤维,松散尖端,亲水涂层和顺磁标记增强,可进行被动可视化。通过11F护套,将导丝推进到腹部(猪1)或胸主动脉(猪2)中,并展开支架。将导丝推进到下腔静脉(猪3)中,并部署腔滤器。进行尸检。通过共识定性评估了手术的成功率,导丝的可见性,可推动性和支架支撑。记录了手术时间。引导线成功进入腹主动脉和下腔静脉。在降主动脉的腹部(猪1)和胸腔(猪2)段中成功部署了支架。 Cava过滤器的定位和部署成功。尸检证明良好的支架和过滤器定位。通过应用的标记,导丝可见度被评定为对于主动脉支架植入是可接受的,并且对于静脉滤器放置是良好的。可操纵性,可推动性和设备支持都很好。基于PEEK的导丝可以在降主动脉的胸段和腹段进行经MRI引导的主动脉支架置入术,并在下腔静脉中放置滤器,并具有良好的设备可见性,并提供良好的可操纵性,可推动性和设备支持。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号