Comparative test-retest reliability of metabolite values assessed with magnetic resonance spectroscopy of the brain. The LCModel versus the manufacturer software.

机译:用大脑的磁共振波谱评估代谢物值的比较重测信度。 LCModel与制造商软件。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: Reproducibility is an essential strength of any diagnostic technique for cross-sectional and longitudinal works. To determine in vivo short-term comparatively, the test-retest reliability of magnetic resonance spectroscopy (MRS) of the brain was compared using the manufacturer's software package and the widely used linear combination of model (LCModel) technique. METHODS: Single-voxel H-MRS was performed in a series of patients with different pathologies on a 1.5 T clinical scanner. Four areas of the brain were explored with the point resolved spectroscopy technique acquisition mode; the echo time was 35 milliseconds and the repetition time was 2000 milliseconds. We enrolled 15 patients for every area, and the intra-individual variations of metabolites were studied in two consecutive scans without removing the patient from the scanner. Curve fitting and analysis of metabolites were made with the software of GE and the LCModel. Spectra non-fulfilling the minimum criteria of quality in relation to linewidths and signaloise ratio were rejected. RESULTS: The intraclass correlation coefficients for the N-acetylaspartate/creatine (NAA/Cr) ratios were 0.93, 0.89, 0.9 and 0.8 for the posterior cingulate gyrus, occipital, prefrontal and temporal regions, respectively, with the GE software. For the LCModel, the coefficients were 0.9, 0.89, 0.87 and 0.84, respectively. For the absolute value of NAA, the GE software was also slightly more reproducible than LCModel. However, for the choline/Cr and myo-inositol/Cr ratios, the LCModel was more reliable than the GE software. The variability we have seen hovers around the percentages observed in previous reports (around 10% for the NAA/Cr ratios). CONCLUSION: We did not find that the LCModel software is superior to the software of the manufacturer. Reproducibility of metabolite values relies more on the observance of the quality parameters than on the software used.
机译:目的:再现性是横截面和纵向工作的任何诊断技术的基本优势。为了比较短期地确定体内,使用制造商的软件包和广泛使用的线性模型组合(LCModel)技术比较了大脑磁共振波谱(MRS)的重测可靠性。方法:在1.5 T临床扫描仪上对一系列具有不同病理的患者进行单素H-MRS。用点分辨光谱技术采集模式探索了大脑的四个区域。回声时间为35毫秒,重复时间为2000毫秒。我们在每个区域招募了15名患者,并且在连续两次扫描中研究了代谢物的个体内变化,而无需从扫描仪中移除患者。用GE和LCModel软件进行曲线拟合和代谢物分析。拒绝满足谱线宽度和信噪比的最低质量标准的光谱被拒绝。结果:使用GE软件,后扣带回,枕叶,额叶前和颞叶区域的N-乙酰天门冬氨酸/肌酸(NAA / Cr)比的组内相关系数分别为0.93、0.89、0.9和0.8。对于LCModel,系数分别为0.9、0.89、0.87和0.84。对于NAA的绝对值,GE软件的重现性也比LCModel高。但是,对于胆碱/ Cr和肌醇/ Cr比率,LCModel比GE软件更可靠。我们已经看到变异性徘徊在先前报告中观察到的百分比附近(NAA / Cr比约为10%)。结论:我们没有发现LCModel软件优于制造商的软件。代谢物值的可重复性更多地取决于对质量参数的遵守,而不是所使用的软件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号