首页> 外文期刊>Neurological Research: An Interdisciplinary Quarterly Journal >A precise, simple, convenient and new method for estimation of intracranial hematoma volume--the formula 2/3Sh.
【24h】

A precise, simple, convenient and new method for estimation of intracranial hematoma volume--the formula 2/3Sh.

机译:一种精确,简单,方便且新颖的颅内血肿体积估计方法-公式2 / 3Sh。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVES: The formula 1/2abc was a relatively reliable technique for the estimation of mostly intracranial hematoma volume, but its accuracy was prone to be affected by some particular shapes of hematoma, such as multinodular, separated and so on. In this work, we aimed to validate a more accurate method for the estimation of intracranial hematoma volume, which were free limitations of axial slices shapes. METHODS: We investigated the computed tomography (CT) scans of 186 patients with intracranial hematoma. The volume values of 186 intracranial hematomas were respectively assessed using five different methods. RESULTS: For the formula 2/3Sh, the excellent correlation coefficient obtained using Pearson and Spearman's coefficients were 0.990 and 0.990, respectively. Meanwhile, the estimated intracranial hematoma volume using the formula 2/3Sh was fairly precise, with a <1% (-0.00+/-0.14, p>0.05) underestimation. However, the intracranial hematoma volume values were estimated by the formulas 1/2abc, Tada and 1/3abc, in comparison with the gold standard (43.16+/-37.55 ml), were 45.98+/-39.97 ml (p>0.05) with a 5% (0.05+/-0.25, p<0.05) overestimation, 48.12+/-41.84 ml (p>0.05) with 10% (0.10+/-0.26, p<0.05) overestimation and 30.65+/-26.65 ml (p<0.05) with a nearly 29% (-0.29+/-0.16, p<0.05) underestimation, respectively. DISCUSSIONS: Owing to the area, length and width of the largest axial hematoma slice clearly marked in CT imaging, the formula 2/3Sh in comparison with other methods was a precise, simple and convenient estimation technique.
机译:目的:公式1 / 2abc是用于估计颅内血肿体积的相对可靠的技术,但其准确性容易受到某些特殊形状的血肿的影响,例如多结节状,分离性等。在这项工作中,我们旨在验证一种更准确的颅内血肿体积估计方法,该方法不受轴向切片形状的限制。方法:我们调查了186例颅内血肿的计算机断层扫描(CT)扫描。使用五种不同方法分别评估了186例颅内血肿的体积值。结果:对于公式2 / 3Sh,使用Pearson系数和Spearman系数获得的优良相关系数分别为0.990和0.990。同时,使用公式2 / 3Sh估算的颅内血肿体积相当精确,低估了<1%(-0.00 +/- 0.14,p> 0.05)。但是,颅内血肿体积值是根据公式1 / 2abc,Tada和1 / 3abc估算的,与金标准液(43.16 +/- 37.55 ml)相比为45.98 +/- 39.97 ml(p> 0.05) 5%(0.05 +/- 0.25,p <0.05)高估,48.12 +/- 41.84 ml(p> 0.05)和10%(0.10 +/- 0.26,p <0.05)高估和30.65 +/- 26.65 ml( p <0.05),分别低估了将近29%(-0.29 +/- 0.16,p <0.05)。讨论:由于最大的轴向血肿切片的面积,长度和宽度在CT成像中清晰地标出,因此与其他方法相比,公式2 / 3Sh是一种精确,简单且方便的估算技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号