...
首页> 外文期刊>Neurogastroenterology and motility >Multichannel electrogastrography under a magnifying glass--an in-depth study on reproducibility of fed state electrogastrograms.
【24h】

Multichannel electrogastrography under a magnifying glass--an in-depth study on reproducibility of fed state electrogastrograms.

机译:放大镜下的多通道胃电描记术-对馈电状态胃电图重现性的深入研究。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We checked on reproducibility of parameters of a multichannel electrogastrogram in adults after intake of typical, applied in electrogastrography, test meals. Recordings of multichannel electrogastrograms were accomplished in four blocks comprising 18 subjects (nine healthy volunteers and nine patients with functional GI disorders) each. Every subject had two examinations taken 1-2 days apart, and a third one was accomplished at least 2 weeks before or after the two other sessions. The registration involved a 30-min fasted and a 2-h postprandial period after one of the meal stimuli tested within a given block: 400 mL water, 400 g yoghurt (378 kcal), a scrambled eggs sandwich (370 kcal), a pancake (355 kcal). From among the parameters reflecting the propagation of the gastric slow waves, the average percentage of slow wave coupling (APSWC) exhibited a good (coefficient of variation for paired examinations CV(p) < or = 10%) to moderate (10 < CV(p) < or = 30%) reproducibility. On the other hand, the reproducibility of the maximum dominant frequency difference and the spatial dominant power difference was found to be unsatisfactory. The reproducibility of the multichannel electrogastrographic parameters did not differ between healthy volunteers and patients with functional GI disorders. Gender or the kind of a test meal did not affect the reproducibility of the electrogastrographic parameters either. The medium-term reproducibility was not any worse than the short-term one. From among the parameters of a multichannel electrogastrogram intended to quantify the propagation of slow waves, only the APSWC offers a reproducibility potentially good enough for clinical applications.
机译:我们在摄入典型的,用于电子胃镜检查的试验餐后,检查了成年人多通道胃电图参数的可重复性。多通道胃电图的记录在四个区域完成,每个区域包括18位受试者(9位健康志愿者和9位功能性GI障碍患者)。每个受试者进行两次考试,相隔1-2天,而第三次考试则至少在另外两节课之前或之后两周完成。在一个给定的时间段内测试一种刺激食物后,禁食30分钟,餐后2小时:400 mL水,400 g酸奶(378 kcal),炒鸡蛋三明治(370 kcal),薄煎饼(355大卡)。在反映胃慢波传播的参数中,慢波耦合(APSWC)的平均百分比表现出良好(配对检查的变异系数CV(p)<或= 10%)至中度(10

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号