首页> 外文期刊>Neurocritical care >Frequency of eye deviation in stroke and non-stroke patients undergoing head CT
【24h】

Frequency of eye deviation in stroke and non-stroke patients undergoing head CT

机译:接受头部CT扫描的中风和非中风患者的眼球偏斜频率

获取原文
获取原文并翻译 | 示例
           

摘要

Background and Purpose: Although conjugate eye deviation (CED) on head CT has been described in patients with acute stroke, the incidence in other patient groups remains unknown. The aim of this study was to determine the frequency of eye deviation on head CT in non-stroke patients compared to patients with acute stroke symptoms. Materials and Methods: Three groups of patients were identified retrospectively: emergency department (ED)/inpatients undergoing head CT for non-stroke symptoms (Group 1), stroke patients receiving intravenous tPA (Group 2), and stroke patients undergoing intra-arterial therapy (Group 3). The presence on head CT of CED, lone eye deviation (LED), and skew deviation (SD) and the angle of deviation were recorded. The NIHSS score was recorded for Groups 2 and 3. Results: CED was present in 17 (14 %) of 120 Group 1 patients, 17 (36 %) of 47 Group 2 patients, and 28 (50 %) of 56 Group 3 patients (p 0.0001). Mean deviation of CED in Groups 1, 2, and 3 was 19 o (range 7-36 o), 25 o (range 6-67 o), and 27 o (range 11-56 o), respectively (p = 0.024). LED was seen in 42 (35 %) of Group 1, 7 (15 %) of Group 2, and 2 (4 %) of Group 3 patients (p 0.0001). There was no significant difference in SD among groups (p = 0.37). CED was associated with a higher National Institutes of Health Stroke Scale (NIHSS) score among stroke patients (p = 0.0008). Conclusion: CED is common in patients with acute stroke. Such deviation may be seen in non-stroke patients, but less commonly and with lesser degrees of deviation.
机译:背景与目的:尽管已经描述了急性卒中患者头部CT上的共轭眼偏(CED),但其他患者组的发病率仍然未知。这项研究的目的是确定与中风急性发作的患者相比,非中风患者的头部CT眼偏斜的频率。资料和方法:回顾性确定三组患者:急诊科(ED)/因非中风症状接受头部CT检查的患者(第1组),接受静脉tPA的中风患者(第2组)和接受动脉内治疗的中风患者(第3组)。记录CED在头颅CT上的存在,单眼偏差(LED)和偏斜偏差(SD)以及偏斜角度。记录了第2组和第3组的NIHSS评分。结果:120例1组患者中有17例(14%)CED,2例2组患者中有17例(36%)和56例3组中有28例(50%) (p <0.0001)。第1组,第2组和第3组中CED的平均偏差分别为19 o(范围7-36 o),25 o(范围6-67 o)和27 o(范围11-56 o)(p = 0.024) 。在第1组的42(35%),第2组的7(15%)和第3组的2(4%)患者中观察到LED(p <0.0001)。各组之间SD差异无统计学意义(p = 0.37)。 CED与中风患者中较高的国立卫生研究院中风量表(NIHSS)得分相关(p = 0.0008)。结论:CED在急性中风患者中很常见。在非卒中患者中可能会出现这种偏差,但这种情况较少见,偏差程度较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号