Reliability of pelvic floor muscle strength assessment using different test positions and tools.

机译:使用不同的测试位置和工具进行骨盆底肌肉力量评估的可靠性。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

AIMS: The aims of this study were to determine the intra-therapist reliability for digital muscle testing and vaginal manometry on maximum voluntary contraction strength and endurance. In addition, we assessed how reliability varied with different tools and different testing positions. METHODS: Subjects included 20 female physiotherapists. The modified Oxford scale was used for the digital muscle testing, and the Peritron perineometer was used for the vaginal resting pressure and vaginal squeeze pressure assessments. Strength and endurance testing were performed. The highest of the maximum voluntary contraction scores was used in strength analysis, and a fatigue index value was calculated from the endurance repetitions. Bent-knee lying, supine, sitting, and standing positions were used. The time interval for between-session reliability was 2-6 weeks. RESULTS: Kappa values for the between-session reliability of digital muscle testing were 0.69, 0.69, 0.86, and 0.79 for the four test positions, respectively. Intra-class correlation coefficient (ICC) values for squeeze pressure readings for the four positions were 0.95, 0.91, 0.96, and 0.92 for maximum voluntary contraction, and 0.05, 0.42, 0.13, and 0.35 for endurance testing. ICC values for resting pressure were 0.74, 0.77, 0.47, and 0.29. CONCLUSIONS: Reliability of digital muscle testing was very good in sitting and good in the other three positions. vaginal resting pressure demonstrated very good reliability in all four positions for maximum voluntary contraction, but was unreliable for endurance testing. Vaginal resting pressure was not reliable in upright positions. Both measurement tools are reliable in certain positions, with manometry demonstrating higher reliability coefficients.
机译:目的:本研究的目的是确定治疗师对数字肌肉测试和阴道测压的最大自愿收缩强度和耐力的可靠性。此外,我们评估了在不同工具和不同测试位置下可靠性如何变化。方法:受试者包括20名女性物理治疗师。改良的牛津秤用于数字肌肉测试,而Peritron会阴仪用于阴道静息压力和阴道挤压压力评估。进行强度和耐力测试。在强度分析中使用最大自愿收缩评分中的最高者,并从耐力重复次数中计算出疲劳指数值。使用屈膝卧位,仰卧位,坐位和站立位。会话间可靠性的时间间隔为2-6周。结果:在四个测试位置,数字肌肉测试的会话间可靠性的Kappa值分别为0.69、0.69、0.86和0.79。四个位置的挤压压力读数的类内相关系数(ICC)值分别是最大主动收缩的0.95、0.91、0.96和0.92,而耐力测试的是0.05、0.42、0.13和0.35。静息压力的ICC值为0.74、0.77、0.47和0.29。结论:数字肌肉测试的可靠性在坐姿方面非常好,在其他三个位置也很不错。阴道静息压在所有四个位置上表现出了很好的可靠性,可以最大程度地进行自愿收缩,但对于耐力测试并不可靠。直立位置的阴道静息压力不可靠。两种测量工具在某些位置都是可靠的,测压法显示出更高的可靠性系数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号