首页> 外文期刊>Near surface geophysics >Geoelectrical mapping of aquifer contamination: a case study from Roorkee, India
【24h】

Geoelectrical mapping of aquifer contamination: a case study from Roorkee, India

机译:含水层污染的地电测绘:来自印度Roorkee的案例研究

获取原文
获取原文并翻译 | 示例
       

摘要

The impact of untreated sewage disposal and sewage irrigation practice around Roorkee, Uttarakhand, India, on groundwater contamination is studied using surface geoelectrical techniques. Electrical resistivity tomography (ERT) and transient electromagnetic (TEM) soundings data were recorded in and around a sewage-irrigated area in Saliyar and Khanjarpur and a remote site where groundwater contamination due to sewage was not expected. The sewage is mainly composed of domestic and municipal waste. Lithology data was used for correlating the resistivity values, which were derived from 2D inversion of resistivity and 1D Occam inversion of TEM data, with the subsurface formation. These two methods were used jointly to increase the reliability of the results in mapping of groundwater contamination. It was thus observed that the sewage pollutants, infiltrated through the soil, reach the shallow unconfined aquifer in and around the polluted area, up to a limited distance from the existent waste disposal sites. The present study suggests that the groundwater present in the shallow unconfined aquifer (<10 m depth) close to waste disposal sites is contaminated. It was noticed that the decrease in the resistivity of a shallow unconfined aquifer is up to 50% in comparison with that of the shallow unconfined aquifer at a remote site located about 20 km north-west of the disposal sites. The extent of the polluted aquifer zone was delineated by comparing its resistivity with that of the same aquifer at a point away from the disposal sites. Thus, the extent of groundwater pollution and relative direction of its flow were also determined qualitatively.
机译:使用地表地电技术研究了印度北阿坎德邦罗尔基附近未经处理的污水处理和污水灌溉实践对地下水污染的影响。在Saliyar和Khanjarpur的污水灌溉区域以及附近地区(预计不会因污水造成地下水污染)中和周围记录电阻层析成像(ERT)和瞬态电磁(TEM)探测数据。污水主要由生活垃圾和城市垃圾组成。岩性数据用于将电阻率值与地下地层相关联,电阻率值源自电阻率的2D反演和TEM数据的1D Occam反演。结合使用这两种方法可以提高绘制地下水污染图结果的可靠性。因此,人们观察到,通过土壤渗透的污水污染物到达了受污染地区及其周围的浅层无限制含水层,与现有废物处理场址之间的距离有限。本研究表明,靠近废物处置场的浅层无限制含水层(<10 m深度)中的地下水受到污染。值得注意的是,与位于处置地点西北约20 km的偏远地点的浅层无限制含水层相比,电阻率的降低高达50%。通过比较其电阻率与远离处置场所的同一含水层的电阻率来描绘受污染的含水层区域的范围。因此,定性地确定了地下水污染的程度和流动的相对方向。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号