Background: During mask ventilation, the mask volume can vary as it is pressurized or when it is squeezed. The change in volume of the mask may affect tidal volumes delivered and difference in inspired (Vti) and expired tidal volumes (Vte). Objectives: To investigate whether hand squeeze and distensibility of the mask during ventilation influences tidal volume measurements. Methods: For both experiments, we ventilated a leak-free mask ventilation model using pressures of 25/5 cm H2O through a t-piece. Vti and Vte were measured. (A) Two consultants performed mask ventilation with (1) consistent hand squeeze, (2) release during inflation and squeeze during expiration, (3) squeeze during inflation, release during expiration, and (4) gentle squeeze. Results: (B) Thirty caregivers performed mask ventilation. Experiment A: Vti was different during consistent hold (1) 8.1 ml (0.4) and loose grip (4) 8.2 ml (0.3), compared to squeezing during inflation (2) 18.9 ml (1.9), or expiration (3) 6.4 ml (3.5). Variance in difference between Vti and Vte occurred only when the mask was squeezed during inflation (-47.4% (101.5)). Experiment B: volumes measured were consistent (intraindividual CV 3-5%, interindividual CV 9-10%). When comparing gas flow rate of 6-10 l/min, volumes increased by approximately 8%, differences in Vti and Vte were small with both flow settings (-0.9% (-3.9-1.4) and -0.6% (-3.3-1.8); n.s.). Conclusion: Variation in mask hold during mask ventilation can influence volume measurement, but this hardly occurs when testing caregivers.
机译:背景:在面罩通气期间,面罩的体积可能会随着加压或挤压而发生变化。面罩的体积变化可能会影响所输送的潮气量以及吸气量(Vti)和呼气潮气量(Vte)的差异。目的:研究通气期间手的挤压和面罩的可扩张性是否会影响潮气量的测量。方法:对于这两个实验,我们通过T型管使用25/5 cm H2O的压力对无泄漏面罩通风模型进行通风。测量Vti和Vte。 (A)两名顾问进行面罩通气,其中:(1)持续用手挤压,(2)充气期间释放,并在呼气时挤压,(3)充气期间挤压,并在​​呼气时释放,(4)轻轻挤压。结果:(B)30名护理人员进行了面罩通气。实验A:在持续抓握(1)8.1 ml(0.4)和松弛抓握(4)8.2 ml(0.3)期间,Vti与充气(2)18.9 ml(1.9)或呼气(3)6.4 ml期间的挤压不同(3.5)。 Vti和Vte之间的差异只有在充气期间挤压面罩时才会出现差异(-47.4%(101.5))。实验B:测得的体积是一致的(个体CV为3-5%,个体间CV为9-10%)。当比较6-10 l / min的气体流速时,体积增加了大约8%,两种流量设置(-0.9%(-3.9-1.4)和-0.6%(-3.3-1.8)时Vti和Vte的差异很小); ns)。结论:面罩通气期间面罩固定的变化会影响体积测量,但是在测试护理人员时几乎不会发生这种情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号