首页> 外文期刊>NDT & E International: Independent Nondestructive Testing and Evaluation >Reducing environmental scattering in industrial computed tomography by system redesign
【24h】

Reducing environmental scattering in industrial computed tomography by system redesign

机译:通过系统重新设计减少工业计算机断层摄影中的环境散射

获取原文
获取原文并翻译 | 示例
           

摘要

X-ray tomographic image quality is degraded by radiation scattered in the sample and the environment. In this paper, a computed tomography (CT) system with 450 kV source is optimized for low environmental scattering. Monte Carlo simulations of different CT-conflgurations predict a reduction of environmental scattering by (81 ± 4)%. An optimized setup is characterized by a large detector housing from thin composite plates, a thin mirror, and cabin walls lined with metallic plates. In radiography experiments, the contrast improves by (22 + 2)% for 50 mm thick aluminium objects and by (35+4)% for 160 mm thick aluminium parts. The improvement in tomographic imaging matches the radiography results.
机译:X射线断层图像的质量会因样品和环境中散布的辐射而降低。本文针对低环境散射优化了具有450 kV源的计算机断层扫描(CT)系统。不同CT配置的蒙特卡洛模拟预测,环境散射降低(81±4)%。优化的设置的特征是大型探测器外壳,由薄的复合板,薄的镜子和衬有金属板的机舱壁组成。在射线照相实验中,对于50毫米厚的铝制物体,对比度提高(22 + 2)%,对于160毫米厚的铝制部件,对比度提高(35 + 4)%。层析成像的改进与射线照相的结果相匹配。