首页> 外文期刊>NDT & E International: Independent Nondestructive Testing and Evaluation >Ultrasonic measurements of undamaged concrete layer thickness in a deteriorated concrete structure
【24h】

Ultrasonic measurements of undamaged concrete layer thickness in a deteriorated concrete structure

机译:超声测量劣化混凝土结构中未损坏的混凝土层厚度

获取原文
获取原文并翻译 | 示例
           

摘要

Ultrasonic wave propagation in deteriorated concrete structures was studied numerically and experimentally. Ultrasonic single-side access immersion pulse-echo and diffuse field measurements were performed in deteriorated concrete structures at 0.5 MHz center frequency. Numerically and experimentally it is shown that the undamaged layer thickness in a deteriorated concrete structure is measurable using pulse-echo measurements when the deterioration depth is larger than the wavelength. The signal overlapping, which occurs in the thin deteriorated layers, can be overcome using diffuse field measurements or a pattern matching technique. The ultrasonic experimental data were shown to be in good agreement with the widely used phenolphthalein test for concrete degradation. (C) 2015 Elsevier Ltd. All rights reserved.
机译:数值研究了超声波在劣化混凝土结构中的传播。在中心频率为0.5 MHz的混凝土结构中进行超声单侧浸没式脉冲回波和散射场测量。数值和实验表明,当损坏深度大于波长时,使用脉冲回波测量可以测量出损坏的混凝土结构中未损坏的层厚度。使用扩散场测量或模式匹配技术可以克服在薄薄的劣化层中发生的信号重叠。超声实验数据表明与广泛用于混凝土降解的酚酞试验吻合。 (C)2015 Elsevier Ltd.保留所有权利。