首页> 外文期刊>Nephron >Serum levels of soluble adhesion molecules in chronic renal failure and dialysis patients.
【24h】

Serum levels of soluble adhesion molecules in chronic renal failure and dialysis patients.

机译:慢性肾功能衰竭和透析患者的血清可溶性粘附分子水平。

获取原文
获取原文并翻译 | 示例
           

摘要

Besides cell-bound adhesion molecules, which are of fundamental importance to a large number of physiological and pathological processes, soluble forms of adhesion molecules have been detected in the circulating blood in recent years. Circulating soluble adhesion molecules appear to be biologically active, and raised levels have been reported in a variety of disorders. In the present study, we used ELISA to measure the serum levels of four soluble adhesion molecules in 23 undialyzed patients with chronic renal failure (CRF), 13 patients on continuous ambulatory peritoneal dialysis (CAPD), 17 on chronic hemodialysis (HD) and 18 healthy controls having a similar mean and distribution of ages. The investigated soluble (s) molecules included intercellular adhesion molecule 1 (sICAM-1), vascular cell adhesion molecule 1 (sVCAM-1), sE-selectin and sP-selectin. sICAM-1 was found to be elevated in patients with CRF (p < 0.05), on CAPD (p < 0.02) and HD (p < 0.0001) compared with the controls but levels did not differ between the three patient groups. The higher sVCAM-1 values found in CRF (p < 0.02), CAPD (p < 0.05) and HD (p < 0.0001) as compared to controls again failed to differentiate the three groups of patients. Soluble E-selectin was also raised in the three groups (p < 0.0001) with no difference between them. Increased sP-selectin was found in CRF (p < 0.05), CAPD (p < 0.02) and in HD patients (p < 0.0001) compared to controls, and levels in HD were significantly higher (p < 0.02) than in CRF patients. Predialysis serum molecule levels did not differ between HD patients treated with cuprophan or with polyacrylonitrile dialyzers. HD sessions with both dialyzers had no effect on sICAM-1, while a decrease (p < 0.02) in sP-selectin was found after dialysis with cuprophan. In undialyzed patients with CRF, regression analysis showed a strong linear correlation between serum creatinine and serum levels of each soluble molecule. These results demonstrate that serum levels of soluble adhesion molecules ICAM-1, VCAM-1, E-selectin and P-selectin are elevated in both undialyzed patients with CRF and patients on CAPD or HD. The elevated serum levels of these proteins probably reflect inadequate clearance as well as enhanced synthesis/release.
机译:除了对许多生理和病理过程至关重要的细胞结合粘附分子外,近年来还在循环血液中检测到可溶性形式的粘附分子。循环可溶性粘附分子似乎具有生物活性,并且已经报道了多种疾病中的水平升高。在本研究中,我们使用ELISA来测量23例未透析的慢性肾功能衰竭(CRF),13例持续性非卧床腹膜透析(CAPD),17例慢性血液透析(HD)和18例患者的四种可溶性粘附分子的血清水平健康对照者的平均年龄分布相似。研究的可溶性分子包括细胞间粘附分子1(sICAM-1),血管细胞粘附分子1(sVCAM-1),sE-选择素和sP-选择素。发现与对照组相比,CRF(s <0.05),CAPD(p <0.02)和HD(p <0.0001)患者的sICAM-1升高,但三组患者的水平没有差异。与对照组相比,在CRF(p <0.02),CAPD(p <0.05)和HD(p <0.0001)中发现较高的sVCAM-1值再次未能区分三组患者。可溶性E-选择素在三组中也升高(p <0.0001),两者之间没有差异。与对照组相比,CRF(p <0.05),CAPD(p <0.02)和HD患者(p <0.0001)发现sP-选择素升高,HD水平明显高于CRF患者(p <0.02)。在用铜磷或聚丙烯腈透析器治疗的HD患者之间,透析前的血清分子水平没有差异。用两个透析器进行的高清疗程对sICAM-1均无影响,而在用铜瓜因透析后发现sP-选择素降低(p <0.02)。在未透析的CRF患者中,回归分析显示血清肌酐与每个可溶性分子的血清水平之间存在很强的线性相关性。这些结果表明,在未透析的CRF患者和CAPD或HD患者中,可溶性粘附分子ICAM-1,VCAM-1,E-选择素和P-选择素的血清水平均升高。这些蛋白质的血清水平升高可能反映了清除不足以及合成/释放增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号