Objective: To compare the segmentation capability of the 2 currently available commercial volumetry software programs with specific segmentation algorithms for pulmonary ground-glass nodules (GGNs) and to assess their measurement accuracy. Materials and Methods: In this study, 55 patients with 66 GGNs underwent unenhanced low-dose CT. GGN segmentation was performed by using 2 volumetry software programs (LungCARE, Siemens Healthcare; LungVCAR, GE Healthcare). Successful nodule segmentation was assessed visually and morphologic features of GGNs were evaluated to determine factors affecting segmentation by both types of software. In addition, the measurement accuracy of the software programs was investigated by using an anthropomorphic chest phantom containing simulated GGNs. Results: The successful nodule segmentation rate was significantly higher in LungCARE (90.9%) than in LungVCAR (72.7%) (p = 0.012). Vascular attachment was a negatively influencing morphologic feature of nodule segmentation for both software programs. As for measurement accuracy, mean relative volume measurement errors in nodules ≥ 10 mm were 14.89% with LungCARE and 19.96% with LungVCAR. The mean relative attenuation measurement errors in nodules ≥ 10 mm were 3.03% with LungCARE and 5.12% with LungVCAR. Conclusion: LungCARE shows significantly higher segmentation success rates than LungVCAR. Measurement accuracy of volume and attenuation of GGNs is acceptable in GGNs ≥ 10 mm by both software programs.
机译:目的:比较目前可用的两个商业量测软件程序与特定的肺磨玻璃结节(GGNs)分割算法的分割能力,并评估其测量精度。材料和方法:在本研究中,对55例66个GGN患者进行了未增强的低剂量CT检查。通过使用2个体积软件程序(LungCARE,西门子医疗; LungVCAR,GE医疗)进行GGN分割。肉眼评估成功的结节分割,并评估GGN的形态特征,以确定影响这两种软件分割的因素。此外,通过使用包含模拟GGN的拟人化胸模来研究软件程序的测量精度。结果:LungCARE(90.9%)的成功结节分割率显着高于LungVCAR(72.7%)(p = 0.012)。对于这两个软件程序,血管附着都是对结节分割的形态学特征的不利影响。至于测量精度,LungCARE≥10 mm结节的平均相对体积测量误差为14.89%,而LungVCAR为19.96%。在LungCARE中,≥10 mm结节的平均相对衰减测量误差为3.03%,而LungVCAR为5.12%。结论:LungCARE显示的分割成功率明显高于LungVCAR。两个软件程序在≥10 mm的GGN中都可以接受GGN的体积和衰减的测量精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号