首页> 外文期刊>Korean journal of radiology: official journal of the Korean Radiological Society >Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: Three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences
【24h】

Qualitative and quantitative assessment of isotropic ankle magnetic resonance imaging: Three-dimensional isotropic intermediate-weighted turbo spin echo versus three-dimensional isotropic fast field echo sequences

机译:各向同性踝磁共振成像的定性和定量评估:三维各向同性中间加权涡轮自旋回波与三维各向同性快速场回波序列

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To compare the image quality of volume isotropic turbo spin echo acquisition (VISTA) imaging method with that of the three-dimensional (3D) isotropic fast field echo (FFE) imaging method applied for ankle joint imaging. Materials and Methods: MR imaging of the ankles of 10 healthy volunteers was performed with VISTA and 3D FFE sequences by using a 3.0 T machine. Two radiologists retrospectively assessed the tissue contrast between fluid and cartilage (F-C), and fluid and the Achilles tendon (F-T) with use of a 4-point scale. For a quantitative analysis, signal-to-noise ratio (SNR) was obtained by imaging phantom, and the contrast ratios (CRs) were calculated between F-T and F-C. Statistical analyses for differences in grades of tissue contrast and CRs were performed. Results: VISTA had significantly superior grades in tissue contrast of F-T (p = 0.001). Results of 3D FFE had superior grades in tissue contrast of F-C, but these result were not statistically significant (p = 0.157). VISTA had significantly superior CRs in F-T (p = 0.002), and 3D FFE had superior CRs in F-C (p = 0.003). The SNR of VISTA was higher than that of 3D FFE (49.24 vs. 15.94). Conclusion: VISTA demonstrates superior tissue contrast between fluid and the Achiles tendon in terms of quantitative and qualitative analysis, while 3D FFE shows superior tissue contrast between fluid and cartilage in terms of quantitative analysis.
机译:目的:比较体积各向同性涡轮自旋回波采集(VISTA)成像方法与三维(3D)各向同性快速场回波(FFE)成像方法在踝关节成像中的图像质量。材料和方法:通过使用3.0 T机,使用VISTA和3D FFE序列对10名健康志愿者的脚踝进行MR成像。两位放射科医生使用4分制量表回顾性评估了液体和软骨(F-C)以及液体和跟腱(F-T)之间的组织对比。为了进行定量分析,通过幻像成像获得信噪比(SNR),并计算F-T和F-C之间的对比度(CR)。对组织对比和CR等级的差异进行统计分析。结果:VISTA在F-T的组织对比度方面具有明显优越的等级(p = 0.001)。 3D FFE的结果在F-C的组织对比度方面具有较高的等级,但这些结果没有统计学意义(p = 0.157)。 VISTA在F-T中具有显着优越的CR(p = 0.002),而3D FFE在F-C中具有卓越的CR(p = 0.003)。 VISTA的信噪比高于3D FFE(49.24对15.94)。结论:从定量和定性分析的角度来看,VISTA证明了液体与足腱之间的组织对比度优越,而在定量分析方面,3D FFE的表现出了液体与软骨之间的组织对比度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号