首页> 外文期刊>Knee surgery, sports traumatology, arthroscopy: official journal of the ESSKA >The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery.
【24h】

The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery.

机译:生物可吸收PLC干涉螺钉的不可预测的材料特性及其在ACL重建手术中的不利影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to look at the clinical outcome of polylactide carbonate (PLC) interference screws in knee ligament reconstruction surgery. We prospectively followed up 59 patients who underwent primary hamstring anterior cruciate ligament (ACL) reconstructions using PLC (Calaxo screw; Smith and Nephew, Andover, MA) screws to secure the graft in the tibial tunnel. The average age was 34 years (range 17-55 years, SD 8.93). Twenty-three (39%) patients presented with complications [synovitis in 15% (nine) patients, prominent tibial swelling in 34% (20) patients and both in seven patients]. In comparison, similar complications were not seen in two groups of 59 age and sex matched patients in whom PLLA (Bio RCI; Smith and Nephew, Andover, MA) screws or Titanium (RCI; Smith and Nephew, Andover, MA) screws were used by the same surgeon. The problems encountered in the PLC screw group did not adversely affect knee stability. Six patients underwent exploration of the tibial tunnel site. A sterile white cheesy substance was removed, leaving an empty tibial tunnel. The ACL graft was found to be well attached to tibial tunnel in all cases. The PLC screw diameter, surface area or tibial tunnel diameter did not have any correlation to the occurrence of complications. Two patients required multiple washouts, one of whom developed a deep infection. The degradation of PLC screws does not follow the gradual and controlled pattern demonstrated in the ovine model. The unpredictable screw degradation, and the reaction to it can lead to serious clinical consequences.
机译:这项研究的目的是看在膝盖韧带重建手术中聚乳酸碳酸酯(PLC)干涉螺钉的临床结果。我们前瞻性地随访了59例患者,他们使用PLC螺钉(Calaxo螺钉; Smith and Nephew,Andover,MA)对原发性ham绳肌前交叉韧带(ACL)进行了重建,以将移植物固定在胫骨隧道中。平均年龄为34岁(范围17-55岁,SD 8.93)。 23例(39%)出现并发症[15%(9)的患者患有滑膜炎,34%(20)的患者以及7例均出现胫骨肿胀]。相比之下,在两组年龄和性别相匹配的患者中,使用PLLA(Bio RCI; Smith and Nephew,Andover,MA)螺钉或钛(RCI; Smith and Nephew,Andover,MA)的两组患者中没有相似的并发症。由同一位外科医生。 PLC螺丝组遇到的问题不会对膝关节稳定性产生不利影响。 6名患者接受了胫骨隧道部位的探查。去除了无菌的白色俗气的物质,留下了一条空的胫骨隧道。发现在所有情况下,ACL移植物都很好地附着在胫骨隧道上。 PLC螺钉直径,表面积或胫骨隧道直径与并发症的发生没有任何关系。两名患者需要多次冲洗,其中一名发生了深部感染。 PLC螺钉的降解不遵循绵羊模型中显示的渐进和受控模式。不可预知的螺丝降解及其反应会导致严重的临床后果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号