PURPOSE: To investigate if the regular use of kV-CBCT notably increases the dose delivered to tumor and surrounding healthy tissues. MATERIAL AND METHODS: Images were obtained using a Varian equipment (OBI version 1.3, 645 to 650 projections in 370 degrees to acquire image), and patients were irradiated at source-tumor distance: 100cm. In vivo measurements were performed using radio-thermoluminescent dosimeters Harshaw-TLD700H (TLD) at skin (anterior-posterior and lateral axis crossing the rotation axis), with a fourth TLD group under the table thanks to a retrolaser. TLD's were calibrated at the kV-CBCT effective energy (64 keV), and the method validated using an anthropomorphic phantom, in which Gafchromic EBT films were also inserted. RESULTS: The phantom study showed that the dose distribution depends on the phantom position relative to the axis and that the doses measured at the phantom surface using TLD and films (good agreement) were maximum at the entrance of the anterior-posterior axis. Their arithmetic mean was equal, or a slightly greater than doses measured at mid-thickness of the phantom and at the level of the rectum (OAR). In vivo measurements performed on the five first patients (125 kV-CBCT) yield a mean skin dose per kV-CBCT varying from 5.8+/-0.1 to 7.3+/-0.2 cGy on the anterior-posterior axis. Lateral skin doses vary from 3.4+/-0.2 to 4.5+/-0.2 cGy. CONCLUSION: Doses delivered by repeated kV-CBCT are not negligible. They should be taken into account, but questions about the RBE to be applied to kilovoltage X-rays are raised.
机译:目的:研究常规使用kV-CBCT是否显着增加了递送至肿瘤和周围健康组织的剂量。材料与方法:使用Varian设备(OBI版本1.3,在370度上进行645至650个投影来获取图像)获得图像,并以源-肿瘤距离100cm照射患者。使用放射线热辐射剂量计Harshaw-TLD700H(TLD)在皮肤上(前后轴和横向轴与旋转轴交叉)进行体内测量,第四台TLD组归功于逆向激光技术。在kV-CBCT有效能量(64 keV)下校准了TLD,并使用拟人幻像对方法进行了验证,其中还插入了Gafchromic EBT膜。结果:体模研究显示剂量分布取决于体模相对于轴的位置,并且使用TLD和胶片(良好一致性)在体模表面测量的剂量在前轴前后轴处最大。它们的算术平均值相等,或略大于在幻影中层厚度和直肠水平(OAR)处测得的剂量。在前五名患者(125 kV-CBCT)上进行的体内测量得出,每kV-CBCT的平均皮肤剂量在前后轴上从5.8 +/- 0.1到7.3 +/- 0.2 cGy不等。皮肤侧面剂量从3.4 +/- 0.2到4.5 +/- 0.2 cGy不等。结论:重复kV-CBCT输送的剂量不可忽略。应该考虑它们,但是提出了有关应用于千伏X射线的RBE的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号