...
首页> 外文期刊>Movement disorders >Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale-III in Parkinson's disease.
【24h】

Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale-III in Parkinson's disease.

机译:定时电机测试电池与帕金森氏病统一帕金森氏病评分表III的比较。

获取原文
获取原文并翻译 | 示例

摘要

The most widely used scale currently available for the clinical evaluation of motor dysfunction in Parkinson's disease (PD)-the Unified Parkinson's Disease Rating Scale-III (UPDRS-III) -is time-consuming, subjective, and has suboptimal sensitivity. A brief timed motor test (TMT) battery could possibly overcome these drawbacks. Two hundred eighty-eight PD patients (disease duration 3.1 years; preceding dopaminergic treatment initiation) were assessed with the UPDRS-III and nine TMTs based on aspects of (a) walking, (b) writing, (c) single and double-handed pegboard performance, (d) finger tapping, and (e) rapid alternating forearm movements. We investigated validity, reliability, responsiveness, and feasibility. Completing the TMT battery took less than 5 minutes. The TMT correlated well with UPDRS-III and disease duration. Two factors explained 61% of the TMT variance, the first represented mainly upper extremity function, the second mainly axial/lower extremity function. Cronbach's alpha was equal forthe TMT and the UPDRS-III (0.8). Test-retest reliability of the TMT sumscore was 0.93 to 0.89 for measurements separated by 3 up to 24 months, whereas UPDRS-III correlations were 0.88 to 0.84. At group level, a trial using "change from baseline" as endpoint requires only 75% of the patients needed with the UPDRS-III when applying the TMT battery, and 57% using the pegboard dexterity test. At patient level, TMT and UPDRS-III were equally responsive. The TMT battery described here is valid, reliable, and feasible. Compared to the UPDRS-III, it is more objective and more sensitive to change. Therefore, it could be a useful tool for both practical and scientific purposes. (c) 2008 Movement Disorder Society.
机译:目前可用于帕金森氏病(PD)运动功能障碍临床评估的最广泛使用的量表-帕金森氏病统一评分量表-III(UPDRS-III)-耗时,主观且敏感性欠佳。简短的定时电动机测试(TMT)电池可能会克服这些缺点。根据(a)行走,(b)书写,(c)单手和双手的方面,对288名PD患者(疾病持续时间3.1年;多巴胺能治疗开始之前)和9个TMT进行了评估。钉板性能,(d)敲击手指和(e)前臂快速交替运动。我们调查了有效性,可靠性,响应性和可行性。完成TMT电池用时不到5分钟。 TMT与UPDRS-III和疾病持续时间密切相关。有两个因素解释了TMT方差的61%,第一个主要代表上肢功能,第二个主要代表轴向/下肢功能。 Cronbach的α值等于TMT和UPDRS-III(0.8)。对于间隔3到24个月的测量,TMT sumscore的重测信度为0.93至0.89,而UPDRS-III相关系数为0.88至0.84。在组一级,使用“从基线变化”作为终点的试验仅要求在应用TMT电池时使用UPDRS-III的患者占75%,使用钉板敏捷性测试的患者占57%。在患者方面,TMT和UPDRS-III的反应相同。这里描述的TMT电池是有效,可靠和可行的。与UPDRS-III相比,它更客观,更敏感。因此,对于实践和科学目的,它都是有用的工具。 (c)2008年运动障碍学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号