Are we nearly halfway to the next major incident after Buncefield? But then, there have been other explosions and fires overseas since Buncefield, including Silver Eagle, Utah (2009), Puerto Rico (2009), Jaipur (2009), Macondo/Deep Horizon (2010), and Venezuela (2012). The explosion and fire at the Buncefield fuel terminal on 11 December 2005 was the result of a sequence of events and activities that had taken place in the days, weeks, months, and years prior to the incident. The primary causes were the failure of two-level instruments on the tank that overflowed; the alarm and overfill protection functions did not operate as a result. Allied to these technical failures was inadequate and poor presentation of information about the status of the plant that prevented diagnosis and recognition that a problem existed.
机译:我们距邦斯菲尔德(Buncefield)之后的下一次重大事件已经快一半了吗?但是自Buncefield以来,海外还有其他爆炸和大火,包括银鹰,犹他州(2009),波多黎各(2009),斋浦尔(2009),马孔多/深地平线(2010)和委内瑞拉(2012)。 2005年12月11日在Buncefield加油站发生的爆炸和火灾是事件发生前几天,几周,几个月和几年中发生的一系列事件和活动的结果。主要原因是水箱上的两级仪器发生故障而造成的。警报和溢出保护功能因此无法运行。与这些技术故障有关的是有关工厂状态的信息不足和表示不充分,从而无法诊断和识别存在问题。